Spectrograph systems

There is a spectrograph computer, spec1m, that controls the spectrograph camera (QHY600) and the spectrograph focuser (Esatto). The computer is a OnLogic CL210-G, same as the pwi1m computer, running Windows 11.

The original QHY is liquid cooled, but the camera has no internal protection against overheating should the cooling loop fail. To try to add a layer of safety, we have a couple of thermocouples taped to the body of the camera. We also run the spectrograph power through a Peltec watchdog, and have a relay that resets the watchdog every minute if the thermocouples are reading acceptable values.

The thermocouples are read by a USB device, a Yoctopuce. The relay is a Kmtronix 2-channel USB relay, controlled by serial interface.

The PrimaLuce Esatto focusser has some internal lights that scatter into the spectrograph at a low level. The only way to remove these is to power the focuser down. This is plausible given that the spectrograph is supposed to be stable. We have run the USB to the focuser through a WandererAstro Ultimate PowerBox V2, which allows for turning the USB off and on, via a simple serial interface that I wrote an Alpaca switch driver for.

We run the QHY600 USB through the Wanderer as well, in case we ever need to reconnect the USB.