software
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
software [2022/12/14 21:58] – holtz | software [2025/05/26 04:45] (current) – holtz | ||
---|---|---|---|
Line 7: | Line 7: | ||
* ASCOM Platform (6.4 - Service Pack 1) | * ASCOM Platform (6.4 - Service Pack 1) | ||
- | * !SiTechExe (0.94N) | + | * SiTechExe (0.94N) |
- | * !SiTech Servo II Driver (9.7) | + | * SiTech Servo II Driver (9.7) |
* MaxImDL (6.20) | * MaxImDL (6.20) | ||
* ACP/ACP Scheduler (8.2.1) | * ACP/ACP Scheduler (8.2.1) | ||
Line 18: | Line 18: | ||
* AnyDesk (5.2.1) | * AnyDesk (5.2.1) | ||
* TigerVNC (1.9.0) | * TigerVNC (1.9.0) | ||
+ | |||
+ | 2022 : fresh install on new computer with Windows 11 | ||
== Initial Software Installation == | == Initial Software Installation == | ||
Line 38: | Line 40: | ||
We use VNC for remote access. Launch TigerVNC, right click the tray icon and go to options. Set authentication password for remote access. | We use VNC for remote access. Launch TigerVNC, right click the tray icon and go to options. Set authentication password for remote access. | ||
- | == !Observatory/ | + | == Observatory/ |
Download and install: | Download and install: | ||
* [[https:// | * [[https:// | ||
Line 49: | Line 51: | ||
Download [[http:// | Download [[http:// | ||
- | Once Clarity II launches successfully hit setup and enter the COM port for the Boltwood II (currently | + | Once Clarity II launches successfully hit setup and enter the COM port for the Boltwood II (currently |
Download and install [[https:// | Download and install [[https:// | ||
Line 57: | Line 59: | ||
In Focusmax, click ‘choose’ next to ‘not connected’. Select the Optec driver. | In Focusmax, click ‘choose’ next to ‘not connected’. Select the Optec driver. | ||
Click properties, to set up the focus properties. | Click properties, to set up the focus properties. | ||
- | Select the COM port for the focuser. Currently | + | Select the COM port for the focuser. Currently |
- | In March 2021, switched to FocusMax v4, needed for new large format camera. License purchased. | + | In March 2021, switched to FocusMax v4, needed for new large format camera. License purchased. |
- | Download camera drivers. Camera | + | Download camera drivers. Camera |
Open the installer, select MaxImDL plugin, install. | Open the installer, select MaxImDL plugin, install. | ||
Move the CCDPlugQSI.dll file from C:/ | Move the CCDPlugQSI.dll file from C:/ | ||
Line 75: | Line 77: | ||
Set up camera using Advanced button on ASCOM setup. | Set up camera using Advanced button on ASCOM setup. | ||
- | Open Servoconfig, | + | Open Servoconfig, |
Open SiTech.exe, config, change config, misc, select COM Port for the telescope. | Open SiTech.exe, config, change config, misc, select COM Port for the telescope. | ||
Dome control is usually done through ACP, but low-level checks can be done through ASCOM Dome Control directly. | Dome control is usually done through ACP, but low-level checks can be done through ASCOM Dome Control directly. | ||
- | Open ASCOM Dome Control, Select dome, and select the !MaxDome II driver. | + | Open ASCOM Dome Control, Select dome, and select the MaxDome II driver. |
- | Click Setup Dome, select COM port (Currently | + | Click Setup Dome, select COM port (Currently |
Now we should be able to connect to everything. It’s time to tweak the setup. | Now we should be able to connect to everything. It’s time to tweak the setup. | ||
- | Check telescope config in !SiTech (Config tab, change config). | + | Check telescope config in SiTech (Config tab, change config). |
Check telescope name (TM61), Aperture (24 inches), and focal length (Telescope is f/5, but effectively f/5.6 due to coma corrector -> Focal length is 5.6*24=134.4 inches). | Check telescope name (TM61), Aperture (24 inches), and focal length (Telescope is f/5, but effectively f/5.6 due to coma corrector -> Focal length is 5.6*24=134.4 inches). | ||
- | Check site !Lat/ | + | Check site Lat/ |
Under Mount Params, check that the mount is set to Equatorial. | Under Mount Params, check that the mount is set to Equatorial. | ||
We haven’t changed any of the other parameters under this tab yet. | We haven’t changed any of the other parameters under this tab yet. | ||
Line 123: | Line 125: | ||
We’re still getting some errors with the dome slit positioning, | We’re still getting some errors with the dome slit positioning, | ||
- | In ACP Preferences, | + | In ACP Preferences, |
+ | |||
+ | === FocusMax === | ||
In Focusmax, go to open -> options. | In Focusmax, go to open -> options. | ||
Enable auto connect for focuser and camera. In Camera, set central region to 50% (for large FOV). In Autofocus, disable max HFD, or set to sufficiently large number. Find a star, manual focus, and do a Vcurve. In Settings/ | Enable auto connect for focuser and camera. In Camera, set central region to 50% (for large FOV). In Autofocus, disable max HFD, or set to sufficiently large number. Find a star, manual focus, and do a Vcurve. In Settings/ | ||
- | In MaxImDL, Observatory Control select the setup tab. Add Telescope (SiTechDLL Telescope) | + | === MaximDl === |
+ | |||
+ | In MaxImDL, Observatory Control select the setup tab. Add Telescope (SiTechDLL Telescope). Do NOT connect to Focuser (FocusMax Focuser Hub) if ACP will be connecting to focusser, other you will get communication hangs leading MaxIM to frezee up! If it auto-detects the weatherstation (Boltwood CS and Davis), make sure to disable them for enable all (click the arrow for more options, then deselect Enable for Connect All) | ||
+ | In maximDL, observatory window, Telescope tab, calibrate to allow point here. I could not get Auto to successfully identify stars, so used Manual given information from ACP plate solve: used scale=0.22 and orientation=0 for QHY 600 as mounted. | ||
+ | |||
+ | using Guider window in expose, calibrate guider: take an image and click on Guide star, then use Calibrate button. Need to select AscomDirect in Autoguider output control, and select telescope (Scitech) with setup button. For some reason, maybe need to change sign of Xspeed (once using ACP, seems like it!). May want to set track box size in Guider/ | ||
+ | |||
+ | |||
+ | === Clarity II === | ||
Clarity II Setup: | Clarity II Setup: | ||
Line 140: | Line 152: | ||
In the interim, if the alert flag is not present ACP can still function (older versions of Clarity also didn’t have this alert bit). Instead ACP will look at the level digits for the individual conditions (cloud, wind, rain, daylight), and trigger the weather script if any of the conditions is at Level 3. | In the interim, if the alert flag is not present ACP can still function (older versions of Clarity also didn’t have this alert bit). Instead ACP will look at the level digits for the individual conditions (cloud, wind, rain, daylight), and trigger the weather script if any of the conditions is at Level 3. | ||
+ | === ACP and Scheduler Setup === | ||
- | == Configuration | + | Note that ACP Config is rsynced, so you can find some of the files below in the rsync location. |
+ | |||
+ | - For ACP, add SchedulerDawnFlats.txt (and Dusk) in / | ||
+ | |||
+ | - add Autoflat.config in / | ||
+ | |||
+ | - edit filename in ImageConfig | ||
+ | |||
+ | - see also / | ||
+ | |||
+ | - Run focusoffsets script, creates FilterInfo.txt in ACP Config, or copy existing FilterInfo.txt don't put offsets in MaximDL or they will get applied twice! | ||
+ | |||
+ | To get webcam images in ACP web interface, setup webcam.py (in ACP Web Data/Doc Root/ | ||
+ | < | ||
+ | < | ||
+ | return "< | ||
+ | </ | ||
+ | << | ||
+ | </ | ||
+ | |||
+ | To get focuser position in ACP web, add focus stuff in ACP Web Data/Doc Root/ | ||
+ | < | ||
+ | <tr title=" | ||
+ | <td class=" | ||
+ | <td id=" | ||
+ | </ | ||
+ | |||
+ | </ | ||
+ | |||
+ | Various asp files plus tiddler files are attached in {{wiki: | ||
- | In maximDL, observatory window, Telescope tab, calibrate to allow point here. I could not get Auto to successfully identify stars, so used Manual given information from ACP plate solve: used scale=0.22 and orientation=0 for QHY 600 as mounted. | ||
- | using Guider window in expose, calibrate guider: take an image and click on Guide star, then use Calibrate button. Need to select AscomDirect | + | Finally, use copy script (in rsync directory) with crontab to rsync files, e.g., every 5 minutes? |
- | For ACP, add SchedulerDawnFlats.txt in /Users/admin/ | + | < |
+ | */15 * * * * / | ||
+ | @reboot /cygdrive/c/Users/Public/ | ||
+ | </code> | ||
- | add Autoflat.config in / | ||
- | edit filename in ImageConfig | + | === AAVSO setup === |
- | see also / | + | Install anaconda Python. Get TortoiseSVN and configure to sync \data\code and \data\plans. Edit \data\plans\scripts\environ.bat to set correct direcctory locations; need to create zip directories; |
+ | run it as admin to set environment variables. Set Windows Scheduler to run sync. bat | ||
- | Run focusoffsets script , creates FilterInfo.txt in ACP Config, or copy existing FilterInfo.txt don't put offsets in MaximDL or they will get applied twice! | ||
software.1671055138.txt.gz · Last modified: 2022/12/14 21:58 by holtz