| Line 1: | Line 1: | ||
| + | ====April 2026==== | ||
| + | |||
| + | A new iodine cell was installed. | ||
| + | |||
| + | We implemented a shutter in the direct calibration channel. | ||
| + | |||
| + | We got the repaired liquid cooled CCD back from QHY and installed it, along with the TCube Edge chiller. | ||
| + | |||
| + | When revisiting spectrograph focus, the Esatto focuser would intermittently time out. As a result, it's uncertain whether the reported focus position is repeatable, e.g., after homing the focuser. Given potential repeatability issues, the focuser was just moved until acceptable images were reached, which is at a currently reported value of 398000. After settling on that, the Esattor focuser was powered off through the Wanderer PowerBox to remove the light source. A final image at this focus is UT260424/ | ||
| + | |||
| + | {{: | ||
| + | {{: | ||
| + | |||
| + | |||
| + | |||
| ====November 2025==== | ====November 2025==== | ||