ACP console log opened 26-Feb-2018 10:02:09 UTC This is ACP version 6.0 (build 14, Special for Wodaski Alt/Az Scope) Licensed to Arne Henden 10:02:09 Start slew to FocusArea... 10:02:09 **Script Error (Tracking has been stopped)** 10:02:09 Source: ASCOM.SiTechDll.Telescope 10:02:09 Message: sttgaSiTech Says: Motor(s) in Blinky Mode! at line 68 column 9. 10:02:09 Script Context: 10:02:09 65: If Util.Prefs.AutoFocus.UseAcquireStar Then 10:02:09 66: Telescope.Tracking = True ' AcquireStar needs tracking scope 10:02:09 67: Else 10:02:09 => 68: Call SUP.StartSlewJ2000("FocusArea", CT.RightAscension, CT.Declination) 10:02:09 ^ 10:02:09 69: Call SUP.WaitForSlew() 10:02:09 70: End If 10:02:09 71: 10:02:09 -- end -- ACP console log closed 26-Feb-2018 10:02:09 UTC