ACP console log opened 14-Feb-2022 02:28:57 UTC This is ACP version 8.3 (build 1, Release 8.3) Licensed to Arne Henden 02:28:57 This is AcquireScheduler V8.2.8 02:28:57 Custom image file path/names are in use 02:28:57 [PreFlip=300 PostFlip=300 AF=180 PU=60] 02:28:57 Hardware GEM pier side reporting is available. 02:28:58 Initializing AcquireSupport V8.3.1 02:28:58 Weather safe, server is Boltwood Cloud Sensor II 02:28:58 User actions detected. 02:28:58 Telescope is ACP->TM61, driver V3 02:28:58 Dome is MaxDome 02:28:59 MaxIm DL is version 6.26 02:28:59 Imager is ASCOM 02:28:59 Using focus offsets and star mags from FilterInfo.txt 02:28:59 Selecting filter SR from previous ACP run at 20220213@034716 UTC 02:28:59 Imager readout modes: 02:28:59 0 is Fast 02:28:59 1 is Normal 02:28:59 Guider is SX Universal (no rotator) 02:28:59 Guider plate scale unknown, guided dither with guider pixels 02:28:59 Max unguided exposure 61 sec. 02:28:59 (assuring that FocusMax is running now...) 02:29:04 Calculated unbinned plate scales (arcsec/pix): H = 0.22 V = 0.22 02:29:04 Calculated field of view (arcmin): H = 35.8 V = 24.0 02:29:04 Plate solving with GSC 1.1 (ok for wider fields) 02:29:04 Mount supports tracking rate offsets 02:29:04 ACPS Observation WASP-13bv(1 of 1) 02:29:04 (belongs to Project Transit, Plan WASP-13bv) 02:29:04 (turning on sidereal tracking) 02:29:04 Pointing updates are enabled 02:29:04 Start slew to WASP-13bv... 02:29:06 (wait for slew to complete) 02:30:28 (slew complete) 02:30:28 Calling TargetStart user action. 02:30:28 [flip check: Tn=380s HAc=-15702s GW=T HAz=-15322s DWz=T WF=no] 02:30:28 Updating pointing... 02:30:28 (taking 10 sec. exposure, SR filter, binning = 2) 02:30:28 (using Fast readout mode) 02:30:28 (starting [RBI] + exposure) 02:30:42 (exposure complete) 02:30:44 (exposure complete and image downloaded) 02:30:46 Image finished 02:30:46 Plate-solve pointing image. 02:30:49 180 image stars found 02:30:50 185 catalog stars found 02:30:51 Solved! 50 stars matched. 02:30:51 Average residual is 0.16 arcsec. 02:30:51 Pointing error is 6.014 arcmin @ angle 298.61 02:30:51 True focal length is 3465.2 mm. 02:30:51 True binned plate scales (arcsec/pix): H = 0.45 V = 0.45 02:30:51 True image center (J2000): 09h 19m 59.3s 33° 55' 49.42" 02:30:51 Imager sky position angle is 182.8 deg. 02:31:08 [sync] pointing model updated 02:31:09 Re-slew to target. 02:31:09 Start slew to WASP-13bv... 02:31:10 (wait for slew to complete) 02:31:20 (slew complete) 02:31:20 Target is now centered. 02:31:20 [flip check: Tn=320s HAc=-15637s GW=T HAz=-15330s DWz=T WF=no] 02:31:20 Calling AcquireImage user action. 02:31:20 Imaging to WASP-13bv-S001-SR-R001-SR 02:31:20 (taking 20 sec. exposure, SR filter, binning = 2) 02:31:21 (using Normal readout mode) 02:31:21 (starting [RBI] + exposure) 02:31:45 (exposure complete) 02:31:47 (exposure complete and image downloaded) 02:31:49 Image finished 02:32:07 Plate-solve WASP-13bv-S001-SR-R001-SR final image. 02:32:10 207 image stars found 02:32:11 185 catalog stars found 02:32:15 Solved! 35 stars matched. 02:32:16 Average residual is 0.17 arcsec. 02:32:16 Pointing error is 0.144 arcmin @ angle 49.24 02:32:16 True focal length is 3465.8 mm. 02:32:16 True binned plate scales (arcsec/pix): H = 0.45 V = 0.45 02:32:16 True image center (J2000): 09h 20m 25.2s 33° 53' 02.44" 02:32:16 Imager sky position angle is 182.8 deg. 02:32:16 Image FWHM is 1.6 arcsec (3.60 pixels) 02:32:16 (avg FWHM = 3.28 arcsec) 02:32:16 Within max error tolerance, no re-slew needed. 02:32:16 Calling ImageComplete user action 02:32:17 PROJNAME=Transit put into fits header 02:32:17 CCD-TPWR=37 put into fits header 02:32:17 (high cadence option, no web previews) 02:32:17 (long exposure, trying to autoguide) 02:32:17 Switching from SR to SR+D25 filter for imaging 02:32:17 No focus change required 02:32:21 (take guider image at initial interval 10 sec) 02:32:35 (guide star SNR=24.8 X=306 Y=237) 02:32:35 (first exposure estimate 1.21 sec) 02:32:38 (guide star SNR=6.8 X=295 Y=228) 02:32:38 (final exposure for guiding 1 sec) 02:32:42 (guide star SNR=6.8 X=296 Y=229) 02:32:49 (autoguiding at 1.00 sec.) 02:32:49 (wait for slew to complete) 02:32:55 (slew complete) 02:32:55 [flip check: Tn=420s HAc=-15543s GW=T HAz=-15135s DWz=T WF=no] 02:32:55 Calling AcquireImage user action. 02:32:55 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25 02:32:55 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:32:55 (using Normal readout mode) 02:32:55 (ex=0.47 ey=1.00) 02:32:55 (guider check OK) 02:32:55 (starting [RBI] + exposure) 02:35:04 (exposure complete) 02:35:06 (exposure complete and image downloaded) 02:35:08 Image finished 02:35:09 Calling ImageComplete user action 02:35:10 PROJNAME=Transit put into fits header 02:35:10 CCD-TPWR=37 put into fits header 02:35:10 (waiting for guider to settle...) 02:35:15 (high cadence option, no web previews) 02:35:15 (long exposure, trying to autoguide) 02:35:15 (autoguider still running...) 02:35:15 [flip check: Tn=420s HAc=-15398s GW=T HAz=-14994s DWz=T WF=no] 02:35:15 Calling AcquireImage user action. 02:35:15 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25 02:35:15 Switching from SR+D25 to SG+D25 filter for imaging 02:35:15 No focus change required 02:35:17 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:35:17 (using Normal readout mode) 02:35:17 (ex=2.64 ey=2.11) 02:35:17 (guider check OK) 02:35:17 (starting [RBI] + exposure) 02:37:27 (exposure complete) 02:37:29 (exposure complete and image downloaded) 02:37:31 Image finished 02:37:31 Calling ImageComplete user action 02:37:32 PROJNAME=Transit put into fits header 02:37:32 CCD-TPWR=36 put into fits header 02:37:32 (waiting for guider to settle...) 02:37:38 (high cadence option, no web previews) 02:37:38 (long exposure, trying to autoguide) 02:37:38 (autoguider still running...) 02:37:38 [flip check: Tn=420s HAc=-15252s GW=T HAz=-14851s DWz=T WF=no] 02:37:38 **DUPLICATE IMAGE NAME - ADDED _dupe-1 02:37:38 Calling AcquireImage user action. 02:37:38 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-1 02:37:38 Switching from SG+D25 to SR+D25 filter for imaging 02:37:38 No focus change required 02:37:44 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:37:44 (using Normal readout mode) 02:37:44 (ex=0.97 ey=0.78) 02:37:44 (guider check OK) 02:37:44 (starting [RBI] + exposure) 02:39:54 (exposure complete) 02:39:56 (exposure complete and image downloaded) 02:39:58 Image finished 02:39:58 Calling ImageComplete user action 02:39:59 PROJNAME=Transit put into fits header 02:40:00 CCD-TPWR=36 put into fits header 02:40:00 (waiting for guider to settle...) 02:40:05 (high cadence option, no web previews) 02:40:05 (long exposure, trying to autoguide) 02:40:05 (autoguider still running...) 02:40:05 [flip check: Tn=420s HAc=-15102s GW=T HAz=-14703s DWz=T WF=no] 02:40:05 **DUPLICATE IMAGE NAME - ADDED _dupe-1 02:40:05 Calling AcquireImage user action. 02:40:05 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-1 02:40:05 Switching from SR+D25 to SG+D25 filter for imaging 02:40:05 No focus change required 02:40:07 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:40:07 (using Normal readout mode) 02:40:07 (ex=0.24 ey=0.24) 02:40:07 (guider check OK) 02:40:07 (starting [RBI] + exposure) 02:42:17 (exposure complete) 02:42:19 (exposure complete and image downloaded) 02:42:21 Image finished 02:42:21 Calling ImageComplete user action 02:42:22 PROJNAME=Transit put into fits header 02:42:23 CCD-TPWR=36 put into fits header 02:42:23 (waiting for guider to settle...) 02:42:28 (high cadence option, no web previews) 02:42:28 (long exposure, trying to autoguide) 02:42:28 (autoguider still running...) 02:42:28 [flip check: Tn=420s HAc=-14955s GW=T HAz=-14560s DWz=T WF=no] 02:42:28 **DUPLICATE IMAGE NAME - ADDED _dupe-2 02:42:28 Calling AcquireImage user action. 02:42:28 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-2 02:42:28 Switching from SG+D25 to SR+D25 filter for imaging 02:42:28 No focus change required 02:42:34 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:42:34 (using Normal readout mode) 02:42:35 (ex=0.22 ey=0.04) 02:42:35 (guider check OK) 02:42:35 (starting [RBI] + exposure) 02:44:44 (exposure complete) 02:44:46 (exposure complete and image downloaded) 02:44:48 Image finished 02:44:48 Calling ImageComplete user action 02:44:50 PROJNAME=Transit put into fits header 02:44:50 CCD-TPWR=35 put into fits header 02:44:50 (waiting for guider to settle...) 02:44:55 (high cadence option, no web previews) 02:44:55 (long exposure, trying to autoguide) 02:44:55 (autoguider still running...) 02:44:55 [flip check: Tn=420s HAc=-14808s GW=T HAz=-14413s DWz=T WF=no] 02:44:55 **DUPLICATE IMAGE NAME - ADDED _dupe-2 02:44:55 Calling AcquireImage user action. 02:44:55 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-2 02:44:55 Switching from SR+D25 to SG+D25 filter for imaging 02:44:55 No focus change required 02:44:57 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:44:57 (using Normal readout mode) 02:44:57 (ex=0.46 ey=0.51) 02:44:57 (guider check OK) 02:44:57 (starting [RBI] + exposure) 02:47:07 (exposure complete) 02:47:09 (exposure complete and image downloaded) 02:47:11 Image finished 02:47:11 Calling ImageComplete user action 02:47:12 PROJNAME=Transit put into fits header 02:47:13 CCD-TPWR=35 put into fits header 02:47:13 (waiting for guider to settle...) 02:47:18 (high cadence option, no web previews) 02:47:18 (long exposure, trying to autoguide) 02:47:18 (autoguider still running...) 02:47:18 [flip check: Tn=420s HAc=-14665s GW=T HAz=-14269s DWz=T WF=no] 02:47:18 **DUPLICATE IMAGE NAME - ADDED _dupe-3 02:47:18 Calling AcquireImage user action. 02:47:18 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-3 02:47:18 Switching from SG+D25 to SR+D25 filter for imaging 02:47:18 No focus change required 02:47:24 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:47:24 (using Normal readout mode) 02:47:24 (ex=0.13 ey=0.36) 02:47:24 (guider check OK) 02:47:24 (starting [RBI] + exposure) 02:49:33 (exposure complete) 02:49:35 (exposure complete and image downloaded) 02:49:37 Image finished 02:49:38 Calling ImageComplete user action 02:49:39 PROJNAME=Transit put into fits header 02:49:39 CCD-TPWR=36 put into fits header 02:49:39 (waiting for guider to settle...) 02:49:44 (high cadence option, no web previews) 02:49:44 (long exposure, trying to autoguide) 02:49:44 (autoguider still running...) 02:49:44 [flip check: Tn=420s HAc=-14518s GW=T HAz=-14122s DWz=T WF=no] 02:49:44 **DUPLICATE IMAGE NAME - ADDED _dupe-3 02:49:44 Calling AcquireImage user action. 02:49:44 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-3 02:49:44 Switching from SR+D25 to SG+D25 filter for imaging 02:49:44 No focus change required 02:49:46 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:49:46 (using Normal readout mode) 02:49:46 (ex=7.84 ey=5.52) 02:49:46 (guider error n/a or too high, try #1) 02:49:48 (ex=0.93 ey=0.93) 02:49:48 (guiding errors within limits) 02:49:48 (guider check OK) 02:49:48 (starting [RBI] + exposure) 02:51:56 (exposure complete) 02:51:59 (exposure complete and image downloaded) 02:52:01 Image finished 02:52:01 Calling ImageComplete user action 02:52:02 PROJNAME=Transit put into fits header 02:52:02 CCD-TPWR=36 put into fits header 02:52:02 (waiting for guider to settle...) 02:52:07 (high cadence option, no web previews) 02:52:07 (long exposure, trying to autoguide) 02:52:07 (autoguider still running...) 02:52:07 [flip check: Tn=420s HAc=-14374s GW=T HAz=-13979s DWz=T WF=no] 02:52:07 **DUPLICATE IMAGE NAME - ADDED _dupe-4 02:52:07 Calling AcquireImage user action. 02:52:07 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-4 02:52:07 Switching from SG+D25 to SR+D25 filter for imaging 02:52:07 No focus change required 02:52:13 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:52:14 (using Normal readout mode) 02:52:14 (ex=0.08 ey=0.36) 02:52:14 (guider check OK) 02:52:14 (starting [RBI] + exposure) 02:54:22 (exposure complete) 02:54:25 (exposure complete and image downloaded) 02:54:28 Image finished 02:54:28 Calling ImageComplete user action 02:54:29 PROJNAME=Transit put into fits header 02:54:29 CCD-TPWR=35 put into fits header 02:54:29 (waiting for guider to settle...) 02:54:34 (high cadence option, no web previews) 02:54:34 (long exposure, trying to autoguide) 02:54:34 (autoguider still running...) 02:54:34 [flip check: Tn=420s HAc=-14227s GW=T HAz=-13831s DWz=T WF=no] 02:54:34 **DUPLICATE IMAGE NAME - ADDED _dupe-4 02:54:34 Calling AcquireImage user action. 02:54:34 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-4 02:54:34 Switching from SR+D25 to SG+D25 filter for imaging 02:54:34 No focus change required 02:54:36 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:54:36 (using Normal readout mode) 02:54:36 (ex=9.22 ey=7.68) 02:54:36 (guider error n/a or too high, try #1) 02:54:38 (ex=3.62 ey=2.50) 02:54:38 (guider error n/a or too high, try #2) 02:54:41 (ex=0.93 ey=0.53) 02:54:41 (guiding errors within limits) 02:54:41 (guider check OK) 02:54:41 (starting [RBI] + exposure) 02:56:51 (exposure complete) 02:56:53 (exposure complete and image downloaded) 02:56:55 Image finished 02:56:55 Calling ImageComplete user action 02:56:56 PROJNAME=Transit put into fits header 02:56:57 CCD-TPWR=35 put into fits header 02:56:57 (waiting for guider to settle...) 02:57:02 (high cadence option, no web previews) 02:57:02 (long exposure, trying to autoguide) 02:57:02 (autoguider still running...) 02:57:02 [flip check: Tn=420s HAc=-14079s GW=T HAz=-13683s DWz=T WF=no] 02:57:02 **DUPLICATE IMAGE NAME - ADDED _dupe-5 02:57:02 Calling AcquireImage user action. 02:57:02 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-5 02:57:03 Switching from SG+D25 to SR+D25 filter for imaging 02:57:03 No focus change required 02:57:09 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 02:57:09 (using Normal readout mode) 02:57:09 (ex=3.24 ey=2.27) 02:57:09 (guider error n/a or too high, try #1) 02:57:11 (ex=3.71 ey=2.41) 02:57:11 (guider error n/a or too high, try #2) 02:57:13 (ex=1.18 ey=0.74) 02:57:13 (guiding errors within limits) 02:57:13 (guider check OK) 02:57:13 (starting [RBI] + exposure) 02:59:23 (exposure complete) 02:59:25 (exposure complete and image downloaded) 02:59:27 Image finished 02:59:28 Calling ImageComplete user action 02:59:29 PROJNAME=Transit put into fits header 02:59:29 CCD-TPWR=35 put into fits header 02:59:29 (waiting for guider to settle...) 02:59:34 (high cadence option, no web previews) 02:59:34 (long exposure, trying to autoguide) 02:59:34 (autoguider still running...) 02:59:34 [flip check: Tn=420s HAc=-13926s GW=T HAz=-13531s DWz=T WF=no] 02:59:34 **DUPLICATE IMAGE NAME - ADDED _dupe-5 02:59:34 Calling AcquireImage user action. 02:59:34 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-5 02:59:34 Switching from SR+D25 to SG+D25 filter for imaging 02:59:34 No focus change required 02:59:36 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 02:59:37 (using Normal readout mode) 02:59:37 (ex=0.12 ey=0.09) 02:59:37 (guider check OK) 02:59:37 (starting [RBI] + exposure) 03:01:45 (exposure complete) 03:01:48 (exposure complete and image downloaded) 03:01:50 Image finished 03:01:50 Calling ImageComplete user action 03:01:51 PROJNAME=Transit put into fits header 03:01:51 CCD-TPWR=35 put into fits header 03:01:51 (waiting for guider to settle...) 03:01:57 (high cadence option, no web previews) 03:01:57 (long exposure, trying to autoguide) 03:01:57 (autoguider still running...) 03:01:57 [flip check: Tn=420s HAc=-13783s GW=T HAz=-13388s DWz=T WF=no] 03:01:57 **DUPLICATE IMAGE NAME - ADDED _dupe-6 03:01:57 Calling AcquireImage user action. 03:01:57 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-6 03:01:57 Switching from SG+D25 to SR+D25 filter for imaging 03:01:57 No focus change required 03:02:03 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:02:04 (using Normal readout mode) 03:02:04 (ex=0.12 ey=0.20) 03:02:04 (guider check OK) 03:02:04 (starting [RBI] + exposure) 03:04:13 (exposure complete) 03:04:15 (exposure complete and image downloaded) 03:04:18 Image finished 03:04:18 Calling ImageComplete user action 03:04:19 PROJNAME=Transit put into fits header 03:04:19 CCD-TPWR=35 put into fits header 03:04:19 (waiting for guider to settle...) 03:04:24 (high cadence option, no web previews) 03:04:24 (long exposure, trying to autoguide) 03:04:24 (autoguider still running...) 03:04:24 [flip check: Tn=420s HAc=-13635s GW=T HAz=-13240s DWz=T WF=no] 03:04:25 **DUPLICATE IMAGE NAME - ADDED _dupe-6 03:04:25 Calling AcquireImage user action. 03:04:25 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-6 03:04:25 Switching from SR+D25 to SG+D25 filter for imaging 03:04:25 No focus change required 03:04:26 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:04:27 (using Normal readout mode) 03:04:27 (ex=0.13 ey=0.08) 03:04:27 (guider check OK) 03:04:27 (starting [RBI] + exposure) 03:06:36 (exposure complete) 03:06:39 (exposure complete and image downloaded) 03:06:41 Image finished 03:06:41 Calling ImageComplete user action 03:06:42 PROJNAME=Transit put into fits header 03:06:43 CCD-TPWR=35 put into fits header 03:06:43 (waiting for guider to settle...) 03:06:48 (high cadence option, no web previews) 03:06:48 (long exposure, trying to autoguide) 03:06:48 (autoguider still running...) 03:06:48 [flip check: Tn=420s HAc=-13490s GW=T HAz=-13096s DWz=T WF=no] 03:06:48 **DUPLICATE IMAGE NAME - ADDED _dupe-7 03:06:48 Calling AcquireImage user action. 03:06:48 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-7 03:06:48 Switching from SG+D25 to SR+D25 filter for imaging 03:06:48 No focus change required 03:06:54 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:06:54 (using Normal readout mode) 03:06:55 (ex=0.24 ey=0.34) 03:06:55 (guider check OK) 03:06:55 (starting [RBI] + exposure) 03:09:04 (exposure complete) 03:09:06 (exposure complete and image downloaded) 03:09:09 Image finished 03:09:09 Calling ImageComplete user action 03:09:10 PROJNAME=Transit put into fits header 03:09:10 CCD-TPWR=35 put into fits header 03:09:10 (waiting for guider to settle...) 03:09:15 (high cadence option, no web previews) 03:09:15 (long exposure, trying to autoguide) 03:09:15 (autoguider still running...) 03:09:15 [flip check: Tn=420s HAc=-13343s GW=T HAz=-12948s DWz=T WF=no] 03:09:15 **DUPLICATE IMAGE NAME - ADDED _dupe-7 03:09:15 Calling AcquireImage user action. 03:09:15 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-7 03:09:15 Switching from SR+D25 to SG+D25 filter for imaging 03:09:15 No focus change required 03:09:17 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:09:17 (using Normal readout mode) 03:09:17 (ex=0.00 ey=0.32) 03:09:17 (guider check OK) 03:09:17 (starting [RBI] + exposure) 03:11:26 (exposure complete) 03:11:29 (exposure complete and image downloaded) 03:11:31 Image finished 03:11:31 Calling ImageComplete user action 03:11:32 PROJNAME=Transit put into fits header 03:11:32 CCD-TPWR=34 put into fits header 03:11:32 (waiting for guider to settle...) 03:11:37 (high cadence option, no web previews) 03:11:37 (long exposure, trying to autoguide) 03:11:37 (autoguider still running...) 03:11:37 [flip check: Tn=420s HAc=-13200s GW=T HAz=-12806s DWz=T WF=no] 03:11:37 **DUPLICATE IMAGE NAME - ADDED _dupe-8 03:11:37 Calling AcquireImage user action. 03:11:37 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-8 03:11:37 Switching from SG+D25 to SR+D25 filter for imaging 03:11:37 No focus change required 03:11:44 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:11:44 (using Normal readout mode) 03:11:44 (ex=0.21 ey=0.03) 03:11:44 (guider check OK) 03:11:44 (starting [RBI] + exposure) 03:13:53 (exposure complete) 03:13:55 (exposure complete and image downloaded) 03:13:57 Image finished 03:13:58 Calling ImageComplete user action 03:13:59 PROJNAME=Transit put into fits header 03:13:59 CCD-TPWR=35 put into fits header 03:13:59 (waiting for guider to settle...) 03:14:04 (high cadence option, no web previews) 03:14:04 (long exposure, trying to autoguide) 03:14:04 (autoguider still running...) 03:14:04 [flip check: Tn=420s HAc=-13053s GW=T HAz=-12659s DWz=T WF=no] 03:14:04 **DUPLICATE IMAGE NAME - ADDED _dupe-8 03:14:04 Calling AcquireImage user action. 03:14:04 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-8 03:14:04 Switching from SR+D25 to SG+D25 filter for imaging 03:14:04 No focus change required 03:14:06 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:14:06 (using Normal readout mode) 03:14:06 (ex=0.05 ey=0.19) 03:14:06 (guider check OK) 03:14:06 (starting [RBI] + exposure) 03:16:15 (exposure complete) 03:16:18 (exposure complete and image downloaded) 03:16:20 Image finished 03:16:21 Calling ImageComplete user action 03:16:22 PROJNAME=Transit put into fits header 03:16:22 CCD-TPWR=35 put into fits header 03:16:22 (waiting for guider to settle...) 03:16:27 (high cadence option, no web previews) 03:16:27 (long exposure, trying to autoguide) 03:16:27 (autoguider still running...) 03:16:27 [flip check: Tn=420s HAc=-12910s GW=T HAz=-12515s DWz=T WF=no] 03:16:27 **DUPLICATE IMAGE NAME - ADDED _dupe-9 03:16:27 Calling AcquireImage user action. 03:16:27 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-9 03:16:27 Switching from SG+D25 to SR+D25 filter for imaging 03:16:27 No focus change required 03:16:33 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:16:33 (using Normal readout mode) 03:16:34 (ex=0.07 ey=0.14) 03:16:34 (guider check OK) 03:16:34 (starting [RBI] + exposure) 03:18:44 (exposure complete) 03:18:46 (exposure complete and image downloaded) 03:18:48 Image finished 03:18:49 Calling ImageComplete user action 03:18:50 PROJNAME=Transit put into fits header 03:18:50 CCD-TPWR=35 put into fits header 03:18:50 (waiting for guider to settle...) 03:18:55 (high cadence option, no web previews) 03:18:55 (long exposure, trying to autoguide) 03:18:55 (autoguider still running...) 03:18:55 [flip check: Tn=420s HAc=-12761s GW=T HAz=-12367s DWz=T WF=no] 03:18:55 **DUPLICATE IMAGE NAME - ADDED _dupe-9 03:18:55 Calling AcquireImage user action. 03:18:55 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-9 03:18:56 Switching from SR+D25 to SG+D25 filter for imaging 03:18:56 No focus change required 03:18:57 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:18:57 (using Normal readout mode) 03:18:58 (ex=0.05 ey=0.19) 03:18:58 (guider check OK) 03:18:58 (starting [RBI] + exposure) 03:21:06 (exposure complete) 03:21:09 (exposure complete and image downloaded) 03:21:11 Image finished 03:21:11 Calling ImageComplete user action 03:21:12 PROJNAME=Transit put into fits header 03:21:12 CCD-TPWR=35 put into fits header 03:21:12 (waiting for guider to settle...) 03:21:18 (high cadence option, no web previews) 03:21:18 (long exposure, trying to autoguide) 03:21:18 (autoguider still running...) 03:21:18 [flip check: Tn=420s HAc=-12619s GW=T HAz=-12224s DWz=T WF=no] 03:21:18 **DUPLICATE IMAGE NAME - ADDED _dupe-10 03:21:18 Calling AcquireImage user action. 03:21:18 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-10 03:21:18 Switching from SG+D25 to SR+D25 filter for imaging 03:21:18 No focus change required 03:21:24 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:21:25 (using Normal readout mode) 03:21:25 (ex=0.00 ey=0.09) 03:21:25 (guider check OK) 03:21:25 (starting [RBI] + exposure) 03:23:34 (exposure complete) 03:23:36 (exposure complete and image downloaded) 03:23:38 Image finished 03:23:39 Calling ImageComplete user action 03:23:40 PROJNAME=Transit put into fits header 03:23:40 CCD-TPWR=35 put into fits header 03:23:40 (waiting for guider to settle...) 03:23:45 (high cadence option, no web previews) 03:23:45 (long exposure, trying to autoguide) 03:23:45 (autoguider still running...) 03:23:45 [flip check: Tn=420s HAc=-12471s GW=T HAz=-12076s DWz=T WF=no] 03:23:45 **DUPLICATE IMAGE NAME - ADDED _dupe-10 03:23:45 Calling AcquireImage user action. 03:23:45 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-10 03:23:45 Switching from SR+D25 to SG+D25 filter for imaging 03:23:45 No focus change required 03:23:47 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:23:47 (using Normal readout mode) 03:23:47 (ex=0.23 ey=0.51) 03:23:47 (guider check OK) 03:23:47 (starting [RBI] + exposure) 03:25:56 (exposure complete) 03:25:59 (exposure complete and image downloaded) 03:26:01 Image finished 03:26:02 Calling ImageComplete user action 03:26:03 PROJNAME=Transit put into fits header 03:26:03 CCD-TPWR=34 put into fits header 03:26:03 (waiting for guider to settle...) 03:26:08 (high cadence option, no web previews) 03:26:08 (long exposure, trying to autoguide) 03:26:08 (autoguider still running...) 03:26:08 [flip check: Tn=420s HAc=-12327s GW=T HAz=-11933s DWz=T WF=no] 03:26:08 **DUPLICATE IMAGE NAME - ADDED _dupe-11 03:26:08 Calling AcquireImage user action. 03:26:08 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-11 03:26:08 Switching from SG+D25 to SR+D25 filter for imaging 03:26:08 No focus change required 03:26:15 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:26:15 (using Normal readout mode) 03:26:15 (ex=0.31 ey=0.04) 03:26:15 (guider check OK) 03:26:15 (starting [RBI] + exposure) 03:28:24 (exposure complete) 03:28:26 (exposure complete and image downloaded) 03:28:28 Image finished 03:28:29 Calling ImageComplete user action 03:28:30 PROJNAME=Transit put into fits header 03:28:30 CCD-TPWR=35 put into fits header 03:28:30 (waiting for guider to settle...) 03:28:35 (high cadence option, no web previews) 03:28:35 (long exposure, trying to autoguide) 03:28:35 (autoguider still running...) 03:28:35 [flip check: Tn=420s HAc=-12180s GW=T HAz=-11785s DWz=T WF=no] 03:28:35 **DUPLICATE IMAGE NAME - ADDED _dupe-11 03:28:35 Calling AcquireImage user action. 03:28:35 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-11 03:28:35 Switching from SR+D25 to SG+D25 filter for imaging 03:28:35 No focus change required 03:28:37 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:28:37 (using Normal readout mode) 03:28:38 (ex=0.05 ey=0.01) 03:28:38 (guider check OK) 03:28:38 (starting [RBI] + exposure) 03:30:46 (exposure complete) 03:30:48 (exposure complete and image downloaded) 03:30:51 Image finished 03:30:51 Calling ImageComplete user action 03:30:52 PROJNAME=Transit put into fits header 03:30:52 CCD-TPWR=35 put into fits header 03:30:52 (waiting for guider to settle...) 03:30:57 (high cadence option, no web previews) 03:30:57 (long exposure, trying to autoguide) 03:30:57 (autoguider still running...) 03:30:57 [flip check: Tn=420s HAc=-12037s GW=T HAz=-11642s DWz=T WF=no] 03:30:58 **DUPLICATE IMAGE NAME - ADDED _dupe-12 03:30:58 Calling AcquireImage user action. 03:30:58 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-12 03:30:58 Switching from SG+D25 to SR+D25 filter for imaging 03:30:58 No focus change required 03:31:04 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:31:04 (using Normal readout mode) 03:31:04 (ex=0.07 ey=0.18) 03:31:04 (guider check OK) 03:31:04 (starting [RBI] + exposure) 03:33:13 (exposure complete) 03:33:16 (exposure complete and image downloaded) 03:33:17 Image finished 03:33:18 Calling ImageComplete user action 03:33:19 PROJNAME=Transit put into fits header 03:33:19 CCD-TPWR=35 put into fits header 03:33:19 (waiting for guider to settle...) 03:33:24 (high cadence option, no web previews) 03:33:24 (long exposure, trying to autoguide) 03:33:24 (autoguider still running...) 03:33:24 [flip check: Tn=420s HAc=-11890s GW=T HAz=-11495s DWz=T WF=no] 03:33:24 **DUPLICATE IMAGE NAME - ADDED _dupe-12 03:33:24 Calling AcquireImage user action. 03:33:24 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-12 03:33:25 Switching from SR+D25 to SG+D25 filter for imaging 03:33:25 No focus change required 03:33:26 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:33:27 (using Normal readout mode) 03:33:27 (ex=0.24 ey=0.08) 03:33:27 (guider check OK) 03:33:27 (starting [RBI] + exposure) 03:35:36 (exposure complete) 03:35:38 (exposure complete and image downloaded) 03:35:41 Image finished 03:35:41 Calling ImageComplete user action 03:35:42 PROJNAME=Transit put into fits header 03:35:42 CCD-TPWR=35 put into fits header 03:35:42 (waiting for guider to settle...) 03:35:47 (high cadence option, no web previews) 03:35:47 (long exposure, trying to autoguide) 03:35:47 (autoguider still running...) 03:35:47 [flip check: Tn=420s HAc=-11747s GW=T HAz=-11352s DWz=T WF=no] 03:35:47 **DUPLICATE IMAGE NAME - ADDED _dupe-13 03:35:47 Calling AcquireImage user action. 03:35:48 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-13 03:35:48 Switching from SG+D25 to SR+D25 filter for imaging 03:35:48 No focus change required 03:35:54 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:35:54 (using Normal readout mode) 03:35:54 (ex=0.33 ey=0.20) 03:35:54 (guider check OK) 03:35:54 (starting [RBI] + exposure) 03:38:03 (exposure complete) 03:38:05 (exposure complete and image downloaded) 03:38:07 Image finished 03:38:08 Calling ImageComplete user action 03:38:09 PROJNAME=Transit put into fits header 03:38:09 CCD-TPWR=34 put into fits header 03:38:09 (waiting for guider to settle...) 03:38:14 (high cadence option, no web previews) 03:38:14 (long exposure, trying to autoguide) 03:38:14 (autoguider still running...) 03:38:14 [flip check: Tn=420s HAc=-11599s GW=T HAz=-11204s DWz=T WF=no] 03:38:14 **DUPLICATE IMAGE NAME - ADDED _dupe-13 03:38:14 Calling AcquireImage user action. 03:38:14 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-13 03:38:14 Switching from SR+D25 to SG+D25 filter for imaging 03:38:14 No focus change required 03:38:16 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:38:16 (using Normal readout mode) 03:38:16 (ex=0.13 ey=0.22) 03:38:16 (guider check OK) 03:38:16 (starting [RBI] + exposure) 03:40:25 (exposure complete) 03:40:27 (exposure complete and image downloaded) 03:40:30 Image finished 03:40:30 Calling ImageComplete user action 03:40:31 PROJNAME=Transit put into fits header 03:40:31 CCD-TPWR=35 put into fits header 03:40:31 (waiting for guider to settle...) 03:40:37 (high cadence option, no web previews) 03:40:37 (long exposure, trying to autoguide) 03:40:37 (autoguider still running...) 03:40:37 [flip check: Tn=420s HAc=-11457s GW=T HAz=-11061s DWz=T WF=no] 03:40:37 **DUPLICATE IMAGE NAME - ADDED _dupe-14 03:40:37 Calling AcquireImage user action. 03:40:37 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-14 03:40:37 Switching from SG+D25 to SR+D25 filter for imaging 03:40:37 No focus change required 03:40:43 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:40:43 (using Normal readout mode) 03:40:43 (ex=0.01 ey=0.33) 03:40:44 (guider check OK) 03:40:44 (starting [RBI] + exposure) 03:42:54 (exposure complete) 03:42:56 (exposure complete and image downloaded) 03:42:58 Image finished 03:42:58 Calling ImageComplete user action 03:42:59 PROJNAME=Transit put into fits header 03:42:59 CCD-TPWR=34 put into fits header 03:42:59 (waiting for guider to settle...) 03:43:04 (high cadence option, no web previews) 03:43:04 (long exposure, trying to autoguide) 03:43:04 (autoguider still running...) 03:43:04 [flip check: Tn=420s HAc=-11309s GW=T HAz=-10913s DWz=T WF=no] 03:43:04 **DUPLICATE IMAGE NAME - ADDED _dupe-14 03:43:04 Calling AcquireImage user action. 03:43:04 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-14 03:43:04 Switching from SR+D25 to SG+D25 filter for imaging 03:43:04 No focus change required 03:43:06 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:43:06 (using Normal readout mode) 03:43:07 (ex=3.75 ey=2.55) 03:43:07 (guider error n/a or too high, try #1) 03:43:08 (ex=0.56 ey=0.48) 03:43:08 (guiding errors within limits) 03:43:08 (guider check OK) 03:43:08 (starting [RBI] + exposure) 03:45:16 (exposure complete) 03:45:19 (exposure complete and image downloaded) 03:45:21 Image finished 03:45:21 Calling ImageComplete user action 03:45:22 PROJNAME=Transit put into fits header 03:45:22 CCD-TPWR=34 put into fits header 03:45:22 (waiting for guider to settle...) 03:45:27 (high cadence option, no web previews) 03:45:27 (long exposure, trying to autoguide) 03:45:28 (autoguider still running...) 03:45:28 [flip check: Tn=420s HAc=-11165s GW=T HAz=-10770s DWz=T WF=no] 03:45:28 **DUPLICATE IMAGE NAME - ADDED _dupe-15 03:45:28 Calling AcquireImage user action. 03:45:28 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-15 03:45:28 Switching from SG+D25 to SR+D25 filter for imaging 03:45:28 No focus change required 03:45:34 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:45:34 (using Normal readout mode) 03:45:34 (ex=0.33 ey=0.07) 03:45:34 (guider check OK) 03:45:34 (starting [RBI] + exposure) 03:47:43 (exposure complete) 03:47:45 (exposure complete and image downloaded) 03:47:47 Image finished 03:47:47 Calling ImageComplete user action 03:47:48 PROJNAME=Transit put into fits header 03:47:48 CCD-TPWR=34 put into fits header 03:47:48 (waiting for guider to settle...) 03:47:54 (high cadence option, no web previews) 03:47:54 (long exposure, trying to autoguide) 03:47:54 (autoguider still running...) 03:47:54 [flip check: Tn=420s HAc=-11018s GW=T HAz=-10623s DWz=T WF=no] 03:47:54 **DUPLICATE IMAGE NAME - ADDED _dupe-15 03:47:54 Calling AcquireImage user action. 03:47:54 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-15 03:47:54 Switching from SR+D25 to SG+D25 filter for imaging 03:47:54 No focus change required 03:47:55 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:47:56 (using Normal readout mode) 03:47:56 (ex=1.43 ey=1.25) 03:47:56 (guider check OK) 03:47:56 (starting [RBI] + exposure) 03:50:05 (exposure complete) 03:50:07 (exposure complete and image downloaded) 03:50:10 Image finished 03:50:11 Calling ImageComplete user action 03:50:12 PROJNAME=Transit put into fits header 03:50:12 CCD-TPWR=35 put into fits header 03:50:12 (waiting for guider to settle...) 03:50:17 (high cadence option, no web previews) 03:50:17 (long exposure, trying to autoguide) 03:50:17 (autoguider still running...) 03:50:17 [flip check: Tn=420s HAc=-10874s GW=T HAz=-10479s DWz=T WF=no] 03:50:17 **DUPLICATE IMAGE NAME - ADDED _dupe-16 03:50:17 Calling AcquireImage user action. 03:50:17 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-16 03:50:17 Switching from SG+D25 to SR+D25 filter for imaging 03:50:17 No focus change required 03:50:23 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:50:24 (using Normal readout mode) 03:50:24 (ex=0.07 ey=0.06) 03:50:24 (guider check OK) 03:50:24 (starting [RBI] + exposure) 03:52:33 (exposure complete) 03:52:36 (exposure complete and image downloaded) 03:52:38 Image finished 03:52:38 Calling ImageComplete user action 03:52:39 PROJNAME=Transit put into fits header 03:52:39 CCD-TPWR=34 put into fits header 03:52:39 (waiting for guider to settle...) 03:52:45 (high cadence option, no web previews) 03:52:45 (long exposure, trying to autoguide) 03:52:45 (autoguider still running...) 03:52:45 [flip check: Tn=420s HAc=-10727s GW=T HAz=-10332s DWz=T WF=no] 03:52:45 **DUPLICATE IMAGE NAME - ADDED _dupe-16 03:52:45 Calling AcquireImage user action. 03:52:45 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-16 03:52:45 Switching from SR+D25 to SG+D25 filter for imaging 03:52:45 No focus change required 03:52:46 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:52:46 (using Normal readout mode) 03:52:47 (ex=0.11 ey=0.11) 03:52:47 (guider check OK) 03:52:47 (starting [RBI] + exposure) 03:54:56 (exposure complete) 03:54:58 (exposure complete and image downloaded) 03:55:00 Image finished 03:55:00 Calling ImageComplete user action 03:55:01 PROJNAME=Transit put into fits header 03:55:02 CCD-TPWR=34 put into fits header 03:55:02 (waiting for guider to settle...) 03:55:07 (high cadence option, no web previews) 03:55:07 (long exposure, trying to autoguide) 03:55:07 (autoguider still running...) 03:55:07 [flip check: Tn=420s HAc=-10584s GW=T HAz=-10188s DWz=T WF=no] 03:55:07 **DUPLICATE IMAGE NAME - ADDED _dupe-17 03:55:07 Calling AcquireImage user action. 03:55:07 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-17 03:55:07 Switching from SG+D25 to SR+D25 filter for imaging 03:55:07 No focus change required 03:55:14 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 03:55:14 (using Normal readout mode) 03:55:14 (ex=0.32 ey=0.08) 03:55:14 (guider check OK) 03:55:14 (starting [RBI] + exposure) 03:57:24 (exposure complete) 03:57:26 (exposure complete and image downloaded) 03:57:28 Image finished 03:57:29 Calling ImageComplete user action 03:57:30 PROJNAME=Transit put into fits header 03:57:30 CCD-TPWR=34 put into fits header 03:57:30 (waiting for guider to settle...) 03:57:35 (high cadence option, no web previews) 03:57:35 (long exposure, trying to autoguide) 03:57:35 (autoguider still running...) 03:57:35 [flip check: Tn=420s HAc=-10436s GW=T HAz=-10040s DWz=T WF=no] 03:57:35 **DUPLICATE IMAGE NAME - ADDED _dupe-17 03:57:35 Calling AcquireImage user action. 03:57:35 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-17 03:57:35 Switching from SR+D25 to SG+D25 filter for imaging 03:57:35 No focus change required 03:57:37 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 03:57:37 (using Normal readout mode) 03:57:37 (ex=0.63 ey=0.32) 03:57:37 (guider check OK) 03:57:37 (starting [RBI] + exposure) 03:59:46 (exposure complete) 03:59:48 (exposure complete and image downloaded) 03:59:50 Image finished 03:59:50 Calling ImageComplete user action 03:59:51 PROJNAME=Transit put into fits header 03:59:52 CCD-TPWR=34 put into fits header 03:59:52 (waiting for guider to settle...) 03:59:57 (high cadence option, no web previews) 03:59:57 (long exposure, trying to autoguide) 03:59:57 (autoguider still running...) 03:59:57 [flip check: Tn=420s HAc=-10294s GW=T HAz=-9898s DWz=T WF=no] 03:59:57 **DUPLICATE IMAGE NAME - ADDED _dupe-18 03:59:57 Calling AcquireImage user action. 03:59:57 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-18 03:59:58 Switching from SG+D25 to SR+D25 filter for imaging 03:59:58 No focus change required 04:00:04 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:00:04 (using Normal readout mode) 04:00:04 (ex=0.37 ey=0.05) 04:00:04 (guider check OK) 04:00:04 (starting [RBI] + exposure) 04:02:13 (exposure complete) 04:02:15 (exposure complete and image downloaded) 04:02:17 Image finished 04:02:18 Calling ImageComplete user action 04:02:19 PROJNAME=Transit put into fits header 04:02:19 CCD-TPWR=34 put into fits header 04:02:19 (waiting for guider to settle...) 04:02:24 (high cadence option, no web previews) 04:02:24 (long exposure, trying to autoguide) 04:02:24 (autoguider still running...) 04:02:24 [flip check: Tn=420s HAc=-10145s GW=T HAz=-9750s DWz=T WF=no] 04:02:24 **DUPLICATE IMAGE NAME - ADDED _dupe-18 04:02:24 Calling AcquireImage user action. 04:02:24 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-18 04:02:24 Switching from SR+D25 to SG+D25 filter for imaging 04:02:24 No focus change required 04:02:26 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:02:26 (using Normal readout mode) 04:02:26 (ex=0.04 ey=0.21) 04:02:26 (guider check OK) 04:02:26 (starting [RBI] + exposure) 04:04:35 (exposure complete) 04:04:38 (exposure complete and image downloaded) 04:04:39 Image finished 04:04:39 Calling ImageComplete user action 04:04:40 PROJNAME=Transit put into fits header 04:04:40 CCD-TPWR=34 put into fits header 04:04:40 (waiting for guider to settle...) 04:04:45 (high cadence option, no web previews) 04:04:45 (long exposure, trying to autoguide) 04:04:45 (autoguider still running...) 04:04:45 [flip check: Tn=420s HAc=-10005s GW=T HAz=-9609s DWz=T WF=no] 04:04:45 **DUPLICATE IMAGE NAME - ADDED _dupe-19 04:04:45 Calling AcquireImage user action. 04:04:45 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-19 04:04:45 Switching from SG+D25 to SR+D25 filter for imaging 04:04:45 No focus change required 04:04:52 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:04:52 (using Normal readout mode) 04:04:52 (ex=0.10 ey=0.80) 04:04:52 (guider check OK) 04:04:52 (starting [RBI] + exposure) 04:07:02 (exposure complete) 04:07:04 (exposure complete and image downloaded) 04:07:06 Image finished 04:07:07 Calling ImageComplete user action 04:07:08 PROJNAME=Transit put into fits header 04:07:08 CCD-TPWR=34 put into fits header 04:07:08 (waiting for guider to settle...) 04:07:23 (high cadence option, no web previews) 04:07:23 (long exposure, trying to autoguide) 04:07:23 (autoguider still running...) 04:07:23 [flip check: Tn=420s HAc=-9847s GW=T HAz=-9451s DWz=T WF=no] 04:07:23 **DUPLICATE IMAGE NAME - ADDED _dupe-19 04:07:23 Calling AcquireImage user action. 04:07:23 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-19 04:07:24 Switching from SR+D25 to SG+D25 filter for imaging 04:07:24 No focus change required 04:07:25 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:07:25 (using Normal readout mode) 04:07:26 (ex=0.19 ey=0.21) 04:07:26 (guider check OK) 04:07:26 (starting [RBI] + exposure) 04:09:36 (exposure complete) 04:09:39 (exposure complete and image downloaded) 04:09:41 Image finished 04:09:41 Calling ImageComplete user action 04:09:42 PROJNAME=Transit put into fits header 04:09:42 CCD-TPWR=34 put into fits header 04:09:42 (waiting for guider to settle...) 04:09:48 (high cadence option, no web previews) 04:09:48 (long exposure, trying to autoguide) 04:09:48 (autoguider still running...) 04:09:48 [flip check: Tn=420s HAc=-9702s GW=T HAz=-9306s DWz=T WF=no] 04:09:48 **DUPLICATE IMAGE NAME - ADDED _dupe-20 04:09:48 Calling AcquireImage user action. 04:09:48 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-20 04:09:48 Switching from SG+D25 to SR+D25 filter for imaging 04:09:48 No focus change required 04:09:54 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:09:54 (using Normal readout mode) 04:09:55 (ex=0.46 ey=0.52) 04:09:55 (guider check OK) 04:09:55 (starting [RBI] + exposure) 04:12:04 (exposure complete) 04:12:06 (exposure complete and image downloaded) 04:12:08 Image finished 04:12:09 Calling ImageComplete user action 04:12:10 PROJNAME=Transit put into fits header 04:12:10 CCD-TPWR=34 put into fits header 04:12:10 (waiting for guider to settle...) 04:12:15 (high cadence option, no web previews) 04:12:15 (long exposure, trying to autoguide) 04:12:15 (autoguider still running...) 04:12:15 [flip check: Tn=420s HAc=-9553s GW=T HAz=-9158s DWz=T WF=no] 04:12:15 **DUPLICATE IMAGE NAME - ADDED _dupe-20 04:12:15 Calling AcquireImage user action. 04:12:15 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-20 04:12:15 Switching from SR+D25 to SG+D25 filter for imaging 04:12:15 No focus change required 04:12:17 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:12:17 (using Normal readout mode) 04:12:17 (ex=0.22 ey=0.04) 04:12:17 (guider check OK) 04:12:17 (starting [RBI] + exposure) 04:14:26 (exposure complete) 04:14:28 (exposure complete and image downloaded) 04:14:30 Image finished 04:14:30 Calling ImageComplete user action 04:14:31 PROJNAME=Transit put into fits header 04:14:32 CCD-TPWR=34 put into fits header 04:14:32 (waiting for guider to settle...) 04:14:37 (high cadence option, no web previews) 04:14:37 (long exposure, trying to autoguide) 04:14:37 (autoguider still running...) 04:14:37 [flip check: Tn=420s HAc=-9411s GW=T HAz=-9015s DWz=T WF=no] 04:14:37 **DUPLICATE IMAGE NAME - ADDED _dupe-21 04:14:37 Calling AcquireImage user action. 04:14:37 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-21 04:14:38 Switching from SG+D25 to SR+D25 filter for imaging 04:14:38 No focus change required 04:14:44 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:14:44 (using Normal readout mode) 04:14:44 (ex=0.32 ey=0.11) 04:14:44 (guider check OK) 04:14:44 (starting [RBI] + exposure) 04:16:53 (exposure complete) 04:16:56 (exposure complete and image downloaded) 04:16:58 Image finished 04:16:58 Calling ImageComplete user action 04:16:59 PROJNAME=Transit put into fits header 04:16:59 CCD-TPWR=34 put into fits header 04:16:59 (waiting for guider to settle...) 04:17:04 (high cadence option, no web previews) 04:17:04 (long exposure, trying to autoguide) 04:17:04 (autoguider still running...) 04:17:04 [flip check: Tn=420s HAc=-9263s GW=T HAz=-8868s DWz=T WF=no] 04:17:04 **DUPLICATE IMAGE NAME - ADDED _dupe-21 04:17:04 Calling AcquireImage user action. 04:17:04 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-21 04:17:05 Switching from SR+D25 to SG+D25 filter for imaging 04:17:05 No focus change required 04:17:06 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:17:06 (using Normal readout mode) 04:17:06 (ex=0.11 ey=0.40) 04:17:06 (guider check OK) 04:17:07 (starting [RBI] + exposure) 04:19:15 (exposure complete) 04:19:17 (exposure complete and image downloaded) 04:19:19 Image finished 04:19:19 Calling ImageComplete user action 04:19:20 PROJNAME=Transit put into fits header 04:19:21 CCD-TPWR=34 put into fits header 04:19:21 (waiting for guider to settle...) 04:19:26 (high cadence option, no web previews) 04:19:27 (long exposure, trying to autoguide) 04:19:27 (autoguider still running...) 04:19:27 [flip check: Tn=420s HAc=-9121s GW=T HAz=-8725s DWz=T WF=no] 04:19:27 **DUPLICATE IMAGE NAME - ADDED _dupe-22 04:19:27 Calling AcquireImage user action. 04:19:27 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-22 04:19:27 Switching from SG+D25 to SR+D25 filter for imaging 04:19:27 No focus change required 04:19:33 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:19:33 (using Normal readout mode) 04:19:33 (ex=0.22 ey=0.04) 04:19:33 (guider check OK) 04:19:34 (starting [RBI] + exposure) 04:21:43 (exposure complete) 04:21:45 (exposure complete and image downloaded) 04:21:47 Image finished 04:21:48 Calling ImageComplete user action 04:21:49 PROJNAME=Transit put into fits header 04:21:49 CCD-TPWR=34 put into fits header 04:21:49 (waiting for guider to settle...) 04:21:54 (high cadence option, no web previews) 04:21:54 (long exposure, trying to autoguide) 04:21:54 (autoguider still running...) 04:21:54 [flip check: Tn=420s HAc=-8973s GW=T HAz=-8578s DWz=T WF=no] 04:21:54 **DUPLICATE IMAGE NAME - ADDED _dupe-22 04:21:54 Calling AcquireImage user action. 04:21:54 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-22 04:21:54 Switching from SR+D25 to SG+D25 filter for imaging 04:21:54 No focus change required 04:21:56 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:21:57 (using Normal readout mode) 04:21:57 (ex=0.42 ey=0.06) 04:21:57 (guider check OK) 04:21:57 (starting [RBI] + exposure) 04:24:06 (exposure complete) 04:24:08 (exposure complete and image downloaded) 04:24:10 Image finished 04:24:11 Calling ImageComplete user action 04:24:12 PROJNAME=Transit put into fits header 04:24:12 CCD-TPWR=34 put into fits header 04:24:12 (waiting for guider to settle...) 04:24:17 (high cadence option, no web previews) 04:24:17 (long exposure, trying to autoguide) 04:24:17 (autoguider still running...) 04:24:17 [flip check: Tn=420s HAc=-8829s GW=T HAz=-8434s DWz=T WF=no] 04:24:17 **DUPLICATE IMAGE NAME - ADDED _dupe-23 04:24:17 Calling AcquireImage user action. 04:24:17 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-23 04:24:17 Switching from SG+D25 to SR+D25 filter for imaging 04:24:17 No focus change required 04:24:24 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:24:24 (using Normal readout mode) 04:24:24 (ex=0.16 ey=0.15) 04:24:24 (guider check OK) 04:24:24 (starting [RBI] + exposure) 04:26:33 (exposure complete) 04:26:35 (exposure complete and image downloaded) 04:26:37 Image finished 04:26:38 Calling ImageComplete user action 04:26:39 PROJNAME=Transit put into fits header 04:26:39 CCD-TPWR=34 put into fits header 04:26:39 (waiting for guider to settle...) 04:26:44 (high cadence option, no web previews) 04:26:44 (long exposure, trying to autoguide) 04:26:44 (autoguider still running...) 04:26:44 [flip check: Tn=420s HAc=-8683s GW=T HAz=-8286s DWz=T WF=no] 04:26:44 **DUPLICATE IMAGE NAME - ADDED _dupe-23 04:26:44 Calling AcquireImage user action. 04:26:44 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-23 04:26:44 Switching from SR+D25 to SG+D25 filter for imaging 04:26:44 No focus change required 04:26:46 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:26:46 (using Normal readout mode) 04:26:46 (ex=0.21 ey=0.09) 04:26:46 (guider check OK) 04:26:46 (starting [RBI] + exposure) 04:28:56 (exposure complete) 04:28:58 (exposure complete and image downloaded) 04:29:00 Image finished 04:29:01 Calling ImageComplete user action 04:29:02 PROJNAME=Transit put into fits header 04:29:02 CCD-TPWR=34 put into fits header 04:29:02 (waiting for guider to settle...) 04:29:07 (high cadence option, no web previews) 04:29:07 (long exposure, trying to autoguide) 04:29:07 (autoguider still running...) 04:29:08 [flip check: Tn=420s HAc=-8539s GW=T HAz=-8143s DWz=T WF=no] 04:29:08 **DUPLICATE IMAGE NAME - ADDED _dupe-24 04:29:08 Calling AcquireImage user action. 04:29:08 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-24 04:29:08 Switching from SG+D25 to SR+D25 filter for imaging 04:29:08 No focus change required 04:29:14 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:29:14 (using Normal readout mode) 04:29:14 (ex=0.42 ey=0.19) 04:29:14 (guider check OK) 04:29:14 (starting [RBI] + exposure) 04:31:23 (exposure complete) 04:31:25 (exposure complete and image downloaded) 04:31:27 Image finished 04:31:28 Calling ImageComplete user action 04:31:29 PROJNAME=Transit put into fits header 04:31:29 CCD-TPWR=34 put into fits header 04:31:29 (waiting for guider to settle...) 04:31:34 (high cadence option, no web previews) 04:31:34 (long exposure, trying to autoguide) 04:31:34 (autoguider still running...) 04:31:34 [flip check: Tn=420s HAc=-8391s GW=T HAz=-7996s DWz=T WF=no] 04:31:34 **DUPLICATE IMAGE NAME - ADDED _dupe-24 04:31:34 Calling AcquireImage user action. 04:31:34 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-24 04:31:34 Switching from SR+D25 to SG+D25 filter for imaging 04:31:34 No focus change required 04:31:36 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:31:36 (using Normal readout mode) 04:31:36 (ex=0.20 ey=0.30) 04:31:36 (guider check OK) 04:31:36 (starting [RBI] + exposure) 04:33:45 (exposure complete) 04:33:47 (exposure complete and image downloaded) 04:33:49 Image finished 04:33:50 Calling ImageComplete user action 04:33:51 PROJNAME=Transit put into fits header 04:33:51 CCD-TPWR=34 put into fits header 04:33:51 (waiting for guider to settle...) 04:33:56 (high cadence option, no web previews) 04:33:56 (long exposure, trying to autoguide) 04:33:56 (autoguider still running...) 04:33:56 [flip check: Tn=420s HAc=-8250s GW=T HAz=-7854s DWz=T WF=no] 04:33:56 **DUPLICATE IMAGE NAME - ADDED _dupe-25 04:33:56 Calling AcquireImage user action. 04:33:56 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-25 04:33:56 Switching from SG+D25 to SR+D25 filter for imaging 04:33:56 No focus change required 04:34:02 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:34:03 (using Normal readout mode) 04:34:03 (ex=0.03 ey=0.76) 04:34:03 (guider check OK) 04:34:03 (starting [RBI] + exposure) 04:36:12 (exposure complete) 04:36:14 (exposure complete and image downloaded) 04:36:16 Image finished 04:36:17 Calling ImageComplete user action 04:36:18 PROJNAME=Transit put into fits header 04:36:18 CCD-TPWR=34 put into fits header 04:36:18 (waiting for guider to settle...) 04:36:23 (high cadence option, no web previews) 04:36:23 (long exposure, trying to autoguide) 04:36:23 (autoguider still running...) 04:36:23 [flip check: Tn=420s HAc=-8101s GW=T HAz=-7706s DWz=T WF=no] 04:36:23 **DUPLICATE IMAGE NAME - ADDED _dupe-25 04:36:23 Calling AcquireImage user action. 04:36:23 Imaging to WASP-13bv-S001-SG+D25-R001-SG+D25_dupe-25 04:36:23 Switching from SR+D25 to SG+D25 filter for imaging 04:36:23 No focus change required 04:36:25 (taking 120 sec. exposure, SG+D25 filter, binning = 2) 04:36:25 (using Normal readout mode) 04:36:25 (ex=0.43 ey=0.15) 04:36:26 (guider check OK) 04:36:26 (starting [RBI] + exposure) 04:38:35 (exposure complete) 04:38:37 (exposure complete and image downloaded) 04:39:18 Image finished 04:39:18 Calling ImageComplete user action 04:39:19 PROJNAME=Transit put into fits header 04:39:19 CCD-TPWR=33 put into fits header 04:39:19 (waiting for guider to settle...) 04:39:24 (high cadence option, no web previews) 04:39:24 (long exposure, trying to autoguide) 04:39:25 (autoguider still running...) 04:39:25 [flip check: Tn=420s HAc=-7920s GW=T HAz=-7524s DWz=T WF=no] 04:39:25 **DUPLICATE IMAGE NAME - ADDED _dupe-26 04:39:25 Calling AcquireImage user action. 04:39:25 Imaging to WASP-13bv-S001-SR+D25-R001-SR+D25_dupe-26 04:39:25 Switching from SG+D25 to SR+D25 filter for imaging 04:39:25 No focus change required 04:39:31 (taking 120 sec. exposure, SR+D25 filter, binning = 2) 04:39:31 (using Normal readout mode) 04:39:31 (ex=0.38 ey=0.49) 04:39:31 (guider check OK) 04:39:31 (starting [RBI] + exposure) 04:41:44 Weather Unsafe! data-file acquisition error: Weather data file is stale (> 60 sec old) 04:41:44 **WEATHER ALERT: The weather has become unsafe! 04:41:45 (exposure complete) 04:41:45 **Script Error** 04:41:46 Source: ACP 04:41:46 Message: The script was aborted. 04:41:46 Location: line 1487 column 13. ACP console log closed 14-Feb-2022 04:41:48 UTC