ACP console log opened 21-Oct-2021 04:26:12 UTC This is ACP version 8.2 (build 7, V8.2 Production Release) Licensed to Arne Henden 04:26:12 This is AcquireScheduler V8.2.5 04:26:12 Custom image file path/names are in use 04:26:12 [PreFlip=300 PostFlip=300 AF=180 PU=60] 04:26:12 Hardware GEM pier side reporting is available. 04:26:13 Initializing AcquireSupport V8.2.10 04:26:13 Weather safe, server is Boltwood Cloud Sensor II 04:26:13 User actions detected. 04:26:13 Telescope is ACP->TM61, driver V3 04:26:14 Dome is MaxDome 04:26:14 MaxIm DL is version 6.26 04:26:14 Imager is ASCOM 04:26:14 Using focus offsets and star mags from FilterInfo.txt 04:26:14 Selecting filter SG from previous ACP run at 20211021@042230 UTC 04:26:14 Imager readout modes: 04:26:15 0 is Fast 04:26:15 1 is Normal 04:26:15 Guider is SX Universal (no rotator) 04:26:15 Guider plate scale unknown, guided dither with guider pixels 04:26:15 Max unguided exposure 59 sec. 04:26:15 (assuring that FocusMax is running now...) 04:26:20 Calculated unbinned plate scales (arcsec/pix): H = 0.22 V = 0.22 04:26:20 Calculated field of view (arcmin): H = 35.8 V = 24.0 04:26:20 Plate solving with GSC 1.1 (ok for wider fields) 04:26:20 Mount supports tracking rate offsets 04:26:20 ACPS Observation test(1 of 1) 04:26:20 (belongs to Project Transit, Plan test) 04:26:20 Pointing updates are enabled 04:26:20 (test within tolerance, no slew needed) 04:26:20 Calling TargetStart user action. 04:26:20 (skipping pointing update, last target close enough) 04:26:20 [flip check: Tn=420s HAc=1081s GW=T HAz=1494s DWz=T WF=no] 04:26:20 (long exposure, trying to autoguide) 04:26:20 Switching from SG to SR filter for imaging 04:26:20 Focus change of -50 steps required 04:26:29 (take guider image at initial interval 10 sec) 04:26:45 (guide star SNR=28.5 X=691 Y=364) 04:26:45 (first exposure estimate 1.05 sec) 04:26:51 (guide star SNR=4.8 X=689 Y=363) 04:26:52 (final exposure for guiding 1 sec) 04:26:56 (guide star SNR=4.7 X=684 Y=360) 04:27:05 (autoguiding at 1.00 sec.) 04:27:05 [flip check: Tn=360s HAc=1127s GW=T HAz=1479s DWz=T WF=no] 04:27:05 Imaging to test-S002-R-R001-SR 04:27:05 (taking 60 sec. exposure, SR filter, binning = 2) 04:27:05 (using Normal readout mode) 04:27:08 (ex=0.79 ey=0.43) 04:27:08 (guider check OK) 04:27:13 (starting exposure) 04:27:44 **Script Error** 04:27:44 Source: ACP 04:27:44 Message: The script was aborted. 04:27:44 Location: line 1440 column 13. 04:27:46 **Script Error** 04:27:46 ACP script error 0x80073B01 from ThinScript.ActiveScript: The resource loader cache doesn't have loaded MUI entry.. ACP console log closed 21-Oct-2021 04:27:46 UTC