ACP console log opened 03-Oct-2021 08:30:03 UTC This is ACP version 8.2 (build 7, V8.2 Production Release) Licensed to Arne Henden 08:30:03 This is AcquireScheduler V8.2.5 08:30:03 Custom image file path/names are in use 08:30:03 [PreFlip=300 PostFlip=300 AF=180 PU=60] 08:30:03 Hardware GEM pier side reporting is available. 08:30:04 Initializing AcquireSupport V8.2.10 08:30:04 Weather safe, server is Boltwood Cloud Sensor II 08:30:04 User actions detected. 08:30:04 Telescope is ACP->TM61, driver V3 08:30:04 Dome is MaxDome 08:30:04 MaxIm DL is version 6.26 08:30:04 Imager is ASCOM 08:30:04 Using focus offsets and star mags from FilterInfo.txt 08:30:04 Selecting filter SR+D34 from previous ACP run at 20211003@082836 UTC 08:30:04 Imager readout modes: 08:30:04 0 is Fast 08:30:04 1 is Normal 08:30:04 Autoguiding is disabled 08:30:04 (assuring that FocusMax is running now...) 08:30:09 Calculated unbinned plate scales (arcsec/pix): H = 0.22 V = 0.22 08:30:09 Calculated field of view (arcmin): H = 35.8 V = 24.0 08:30:09 Plate solving with GSC 1.1 (ok for wider fields) 08:30:09 Mount supports tracking rate offsets 08:30:09 ACPS Observation TIC 276360911.01 (1 of 1) 08:30:09 (belongs to Project Transit, Plan 211003) 08:30:09 Pointing updates are enabled 08:30:09 (TIC 276360911.01 within tolerance, no slew needed) 08:30:09 Calling TargetStart user action. 08:30:09 (skipping pointing update, last target close enough) 08:30:09 [flip check: Tn=420s HAc=15336s GW=T HAz=15748s DWz=T WF=no] 08:30:09 [flip check: Tn=360s HAc=15336s GW=T HAz=15688s DWz=T WF=no] 08:30:09 Imaging to TIC 276360911.01 -S055-SR-R001-SR 08:30:09 Switching from SR+D34 to SR filter for imaging 08:30:09 No focus change required 08:30:12 (taking 60 sec. exposure, SR filter, binning = 2) 08:30:12 (using Normal readout mode) 08:30:13 (starting exposure) 08:31:16 (exposure complete) 08:31:19 (exposure complete and image downloaded) 08:31:21 Image finished 08:31:26 Plate-solve TIC 276360911.01 -S055-SR-R001-SR final image. 08:31:29 5300 image stars found 08:31:30 448 catalog stars found 08:31:31 Solved! 111 stars matched. 08:31:31 Average residual is 0.2 arcsec. 08:31:31 Pointing error is 1.186 arcmin @ angle 82.33 08:31:31 (pointing corrector updated with this observation) 08:31:31 True focal length is 3556.1 mm. 08:31:31 True binned plate scales (arcsec/pix): H = 0.44 V = 0.44 08:31:31 True image center (J2000): 21h 56m 21.2s 55° 44' 36.98" 08:31:31 Imager sky position angle is 182.4 deg. 08:31:31 Image FWHM is 2.8 arcsec (6.48 pixels) 08:31:31 (avg FWHM = 2.72 arcsec) 08:31:31 Within max error tolerance, no re-slew needed. 08:31:31 Calling ImageComplete user action 08:31:32 PROJNAME=Transit put into fits header 08:31:33 CCD-TPWR=59 put into fits header 08:31:33 [flip check: Tn=360s HAc=15420s GW=T HAz=15772s DWz=T WF=no] 08:31:33 Imaging to TIC 276360911.01 -S055-SR+D25-R001-SR+D25 08:31:33 Switching from SR to SR+D25 filter for imaging 08:31:33 No focus change required 08:31:37 (taking 60 sec. exposure, SR+D25 filter, binning = 2) 08:31:38 (using Normal readout mode) 08:31:38 (starting exposure) 08:32:42 (exposure complete) 08:32:44 (exposure complete and image downloaded) 08:32:46 Image finished 08:32:51 Plate-solve TIC 276360911.01 -S055-SR+D25-R001-SR+D25 final image. 08:32:57 7034 image stars found 08:32:58 448 catalog stars found 08:33:00 ** Failed to solve plate, possibly due to input plate scale being too far off. 08:33:00 Calling ImageComplete user action 08:33:01 PROJNAME=Transit put into fits header 08:33:01 CCD-TPWR=59 put into fits header 08:33:01 [flip check: Tn=360s HAc=15509s GW=T HAz=15860s DWz=T WF=no] 08:33:01 Imaging to TIC 276360911.01 -S055-SR+D34-R001-SR+D34 08:33:01 Switching from SR+D25 to SR+D34 filter for imaging 08:33:01 No focus change required 08:33:03 (taking 60 sec. exposure, SR+D34 filter, binning = 2) 08:33:03 (using Normal readout mode) 08:33:03 (starting exposure) 08:34:07 (exposure complete) 08:34:09 (exposure complete and image downloaded) 08:34:11 Image finished 08:34:16 Plate-solve TIC 276360911.01 -S055-SR+D34-R001-SR+D34 final image. 08:34:20 5894 image stars found 08:34:21 448 catalog stars found 08:34:22 ** Failed to solve plate, possibly due to input plate scale being too far off. 08:34:22 Calling ImageComplete user action 08:34:23 PROJNAME=Transit put into fits header 08:34:23 CCD-TPWR=59 put into fits header 08:34:23 Calling TargetEnd user action 08:34:23 SchedulerData.mdb size: 6443008 08:34:24 Run complete ACP console log closed 03-Oct-2021 08:34:24 UTC