ACP console log opened 02-Oct-2017 02:09:34 UTC This is ACP version 6.0 (build 14, Special for Wodaski Alt/Az Scope) Licensed to Arne Henden 02:09:34 This is AcquireScheduler V3.5.2 02:09:34 Custom image file path/names are in use 02:09:34 Custom auto-flip parameters are in use 02:09:34 PreFlip=300 PostFlip=120 AF=300 PU=60 02:09:34 Hardware GEM pier side reporting is available. 02:09:35 Initializing AcquireSupport V6.0.7 02:09:35 Weather safe, server is Boltwood Cloud Sensor II 02:09:35 Telescope is ACP->ACP->TMO61, driver V3 02:09:35 Dome is MaxDome 02:09:36 MaxIm DL/CCD is version 5.18 02:09:36 Imager is QSI Universal 02:09:36 Imager readout modes: 02:09:36 0 is Image Quality 02:09:36 Guider is SX Universal(internal/off-axis) 02:09:36 Calculated unbinned plate scales (arcsec/pix): H = 0.33 V = 0.33 02:09:36 Calculated field of view (arcmin): H = 18.4 V = 13.8 02:09:36 Using focus offsets from FilterInfo.txt 02:09:36 **Script Error (Tracking has been stopped)** 02:09:36 Source: ACP.AcquireSupport 02:09:36 Message: FilterInfo.txt has more offset entries than filters in the camera at line 792 column 5. 02:09:36 Script Context: 02:09:36 789: ' Support library 02:09:36 790: ' 02:09:36 791: Set SUP = CreateObject("ACP.AcquireSupport") ' Support methods here 02:09:36 => 792: Call SUP.Initialize() ' Do initialization (may log) 02:09:36 ^ 02:09:36 793: 02:09:36 794: cdir = ACPApp.Path & "\Calibration" ' Cal library directory 02:09:36 795: 02:09:36 -- end -- ACP console log closed 02-Oct-2017 02:09:36 UTC