ACP console log opened 01-Feb-2017 03:13:05 UTC This is ACP version 6.0 (build 14, Special for Wodaski Alt/Az Scope) Licensed to Arne Henden 03:13:05 This is AcquireScheduler V3.5.2 03:13:05 Custom image file path/names are in use 03:13:05 Custom auto-flip parameters are in use 03:13:05 PreFlip=300 PostFlip=120 AF=300 PU=60 03:13:05 Hardware GEM pier side reporting is available. 03:13:06 Initializing AcquireSupport V6.0.7 03:13:07 Weather safe, server is Boltwood Cloud Sensor II 03:13:07 Telescope is ACP->ACP->TMO61, driver V3 03:13:08 Dome is MaxDome 03:13:09 MaxIm DL/CCD is version 5.18 03:13:09 Imager is QSI Universal 03:13:09 Imager readout modes: 03:13:09 0 is Image Quality 03:13:09 Guider is SX Universal(internal/off-axis) 03:13:09 Calculated unbinned plate scales (arcsec/pix): H = 0.33 V = 0.33 03:13:09 Calculated field of view (arcmin): H = 18.4 V = 13.8 03:13:09 Using focus offsets from FilterInfo.txt 03:13:09 ACPS Observation New Observation(1 of 1) 03:13:09 (belongs to Project Stein, Plan YZ_Cnc) 03:13:09 Pointing updates are enabled 03:13:09 (New Observation within tolerance, no slew needed) 03:13:09 [flip check: Tn=360s HAc=-11973s GW=T HAz=-11612s DWz=T WF=no] 03:13:09 Imaging to YZ_Cnc_V_20170201_031309 03:13:09 (taking 60 sec. exposure, V filter, binning = 1) 03:13:09 (using Image Quality readout mode) 03:13:09 (starting exposure) 03:14:31 (exposure complete and image downloaded) 03:14:31 Image finished 03:14:34 Plate-solve YZ_Cnc_V_20170201_031309 final image. 03:14:36 158 image stars found 03:14:37 74 catalog stars found 03:14:37 ** The calculated plate scale is extremely different from the configured plate scale. Solution is suspect. 03:14:41 Run complete ACP console log closed 01-Feb-2017 03:14:41 UTC