ACP console log opened 02-Dec-2015 06:59:22 UTC This is ACP version 6.0 (build 14, Special for Wodaski Alt/Az Scope) Licensed to Arne Henden 06:59:22 This is AcquireScheduler V3.5.2 06:59:22 Custom image file path/names are in use 06:59:22 Custom auto-flip parameters are in use 06:59:22 PreFlip=300 PostFlip=120 AF=300 PU=60 06:59:22 Hardware GEM pier side reporting is available. 06:59:23 Initializing AcquireSupport V6.0.7 06:59:24 Weather safe, server is Boltwood Cloud Sensor II 06:59:24 Telescope is ACP->ACP->TMO61, driver V3 06:59:24 Dome is MaxDome 06:59:24 MaxIm DL/CCD is version 5.18 06:59:24 Imager is QSI Universal 06:59:24 Imager readout modes: 06:59:24 0 is Image Quality 06:59:24 Guider is SX Universal(internal/off-axis) 06:59:24 Calculated unbinned plate scales (arcsec/pix): H = 0.33 V = 0.33 06:59:24 Calculated field of view (arcmin): H = 18.4 V = 13.8 06:59:24 Using focus offsets from FilterInfo.txt 06:59:24 ACPS Observation SA68_216(1 of 1) 06:59:24 (belongs to Project Landolt_2, Plan SA68_216) 06:59:24 (turning on sidereal tracking) 06:59:24 Pointing updates are enabled 06:59:24 Start slew to SA68_216... 06:59:24 **Script Error (Tracking has been stopped)** 06:59:25 Source: ASCOM.SiTechDll.Telescope 06:59:25 Message: sttgaSiTech Says: Motor(s) in Blinky Mode! at line 1741 column 9. 06:59:25 Script Context: 06:59:25 1738: SUP.CalcSimImageCoordinates TargetRA, TargetDec ' Calculate simulator image 06:59:25 1739: End If 06:59:25 1740: Else 06:59:25 => 1741: SUP.StartSlewJ2000 OBS.Name, TargetRA, TargetDec ' START THE SLEW 06:59:25 ^ 06:59:25 1742: End If 06:59:25 1743: If SUP.HaveRotator Then SUP.StartRotateToPA OBS.PA, TargetRA ' Always start rotator slew 06:59:25 1744: 06:59:25 -- end -- ACP console log closed 02-Dec-2015 06:59:25 UTC