ACP console log opened 30-Apr-2014 02:45:41 UTC This is ACP version 6.0 (build 14, Special for Wodaski Alt/Az Scope) Licensed to Arne Henden 02:45:41 This is AcquireScheduler V3.5.2 02:45:41 Custom image file path/names are in use 02:45:41 Custom auto-flip parameters are in use 02:45:41 PreFlip=300 PostFlip=120 AF=300 PU=60 02:45:41 Hardware GEM pier side reporting is available. 02:45:42 Initializing AcquireSupport V6.0.7 02:45:42 Weather safe, server is Boltwood Cloud Sensor II 02:45:42 Telescope is ACP->TMO, driver V3 02:45:42 Dome is MaxDome 02:45:42 MaxIm DL/CCD is version 5.18 02:45:42 Imager is QSI Universal 02:45:42 Imager readout modes: 02:45:42 0 is Use Adv Dialog 02:45:42 1 is Image Quality 02:45:42 2 is Fast Readout 02:45:42 Guider is SX Universal(internal/off-axis) 02:45:42 Calculated unbinned plate scales (arcsec/pix): H = 0.33 V = 0.33 02:45:42 Calculated field of view (arcmin): H = 18.4 V = 13.8 02:45:42 Using focus offsets from FilterInfo.txt 02:45:42 **Script Error (Tracking has been stopped)** 02:45:42 Source: ACP.AcquireSupport 02:45:42 Message: FilterInfo.txt has fewer offset entries than filters in the camera at line 792 column 5. 02:45:42 Script Context: 02:45:42 789: ' Support library 02:45:42 790: ' 02:45:42 791: Set SUP = CreateObject("ACP.AcquireSupport") ' Support methods here 02:45:42 => 792: Call SUP.Initialize() ' Do initialization (may log) 02:45:42 ^ 02:45:42 793: 02:45:42 794: cdir = ACPApp.Path & "\Calibration" ' Cal library directory 02:45:42 795: 02:45:42 -- end -- ACP console log closed 30-Apr-2014 02:45:42 UTC