Log opened at Tue, Feb 07 2023 12:41:29 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 9.0.4 Part of ACP Expert 9.0 Release Full license: Arne Henden 2023-02-07 12:41:29.7: Periodic AF schedule reset. Interval is now 1.0 hours 2023-02-07 12:41:29.7: Last AutoFocus was completed at 07-Feb-2023 04:30:03 UTC 2023-02-07 12:41:29.7: Autofocus will be done ASAP. 2023-02-07 12:41:29.7: ++ Auto Focus ++ 2023-02-07 12:41:29.7: Doing periodic autofocus. 2023-02-07 12:41:29.7: Start special ACP AutoFocus script for scheduler 2023-02-07 12:43:14.2: ** Autofocus failed (n=1), will retry ASAP after 0 min. 2023-02-07 12:43:14.2: Rising plan delay enabled for Plan HAT199_01773: 2023-02-07 12:43:14.2: 595 min. remaining to meet strict constraints. 2023-02-07 12:43:14.2: 5 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.2: deferred (rising) for 4 min, until 07-Feb-2023 12:47:29 UTC 2023-02-07 12:43:14.2: Rising plan delay enabled for Plan HR_Lyr: 2023-02-07 12:43:14.2: 531 min. remaining to meet strict constraints. 2023-02-07 12:43:14.2: 1 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.2: ending rising plan delay. Plan is now eligible. 2023-02-07 12:43:14.3: Rising plan delay enabled for Plan HR_Lyr: 2023-02-07 12:43:14.3: 531 min. remaining to meet strict constraints. 2023-02-07 12:43:14.3: 1 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.3: ending rising plan delay. Plan is now eligible. 2023-02-07 12:43:14.3: Rising plan delay enabled for Plan M56_V6: 2023-02-07 12:43:14.3: 556 min. remaining to meet strict constraints. 2023-02-07 12:43:14.3: 1 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.3: deferred (rising) for 0 min, until 07-Feb-2023 12:43:17 UTC 2023-02-07 12:43:14.3: Rising plan delay enabled for Plan M56_V6: 2023-02-07 12:43:14.3: 556 min. remaining to meet strict constraints. 2023-02-07 12:43:14.3: 1 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.3: deferred (rising) for 0 min, until 07-Feb-2023 12:43:17 UTC 2023-02-07 12:43:14.3: Rising plan delay enabled for Plan V1154_Cyg: 2023-02-07 12:43:14.3: 611 min. remaining to meet strict constraints. 2023-02-07 12:43:14.3: 13 min. remaining for the plan to fit before dawn. 2023-02-07 12:43:14.3: deferred (rising) for 12 min, until 07-Feb-2023 12:55:42 UTC 2023-02-07 12:43:14.3: Dispatcher cycle time: 0.1 sec. 2023-02-07 12:43:14.3: Acquire data for Observation HR_Lyr... 2023-02-07 12:43:14.3: (belongs to Project AAVSO_survey_HQ_AUTO_ver3464, Plan HR_Lyr) 2023-02-07 12:43:14.3: ++ Auto Focus ++ 2023-02-07 12:43:14.3: Doing periodic autofocus. 2023-02-07 12:43:14.3: Start special ACP AutoFocus script for scheduler 2023-02-07 12:44:38.0: ** Autofocus failed (n=2), will retry ASAP after 5 min. 2023-02-07 12:44:38.1: Send Observation HR_Lyr to ACP Sequencer 2023-02-07 12:59:42.3: ACP data acquisition failed for Observation HR_Lyr. 2023-02-07 12:59:42.3: (Observation HR_Lyr interrupted by acquisition process failure.) 2023-02-07 12:59:42.7: ++ Auto Focus ++ 2023-02-07 12:59:42.7: Doing periodic autofocus. 2023-02-07 12:59:42.7: Start special ACP AutoFocus script for scheduler 2023-02-07 13:02:24.3: ** Autofocus failed (n=3), will retry ASAP after 10 min. 2023-02-07 13:14:33.5: ++ Dawn Flats ++ 2023-02-07 13:14:33.5: Start ACP AutoFlat script for Dawn flats 2023-02-07 13:32:53.6: -- Observatory Shutdown -- 2023-02-07 13:32:53.6: Weather safety is now disabled 2023-02-07 13:32:53.6: Start ACP Sequencer's ShutdownObs script 2023-02-07 13:34:20.3: Weather safety is re-enabled 2023-02-07 19:36:08.7: -- Weather Unsafe -- 2023-02-07 20:33:00.5: ++ Weather Safe ++ 2023-02-07 20:53:52.7: -- Weather Unsafe -- 2023-02-07 23:02:58.0: ++ Weather Safe ++ 2023-02-07 23:30:30.7: -- Weather Unsafe -- 2023-02-08 01:47:15.1: ++ Weather Safe ++ 2023-02-08 02:09:59.6: -- Weather Unsafe -- 2023-02-08 02:32:05.7: ++ Weather Safe ++ 2023-02-08 05:03:37.2: -- Weather Unsafe -- 2023-02-08 05:39:15.5: ++ Weather Safe ++ 2023-02-09 19:05:48.8: -- Weather Unsafe -- 2023-02-09 19:52:20.8: ++ Weather Safe ++ 2023-02-09 20:16:25.2: -- Weather Unsafe -- 2023-02-09 20:37:27.3: ++ Weather Safe ++ 2023-02-10 02:49:30.4: -- Weather Unsafe -- 2023-02-10 03:11:09.8: ACPSequencer: Failed to get ACP's DispatcherEnabled property. ACP is compromised. 2023-02-10 03:11:09.8: Unable to cast COM object of type 'ACP.UtilClass' to interface type 'ACP._Util'. This operation failed because the QueryInterface call on the COM component for the interface with IID '{854E05FF-33F8-49E7-83A5-49EC706F8F7E}' failed due to the following error: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA). 2023-02-10 03:11:09.8: **ACP HAS BECOME COMPROMISED: 2023-02-10 03:11:09.8: Scheduler depends on ACP and yet ACP is frozen, dead, or otherwise compromised. 2023-02-10 03:11:09.8: If this happens again, please look at ACP. Is it running? Is a fatal error box visible? Is it frozen? 2023-02-10 03:11:09.8: Usually this is a result of a device or USB failure or lock-up. 2023-02-10 03:11:09.8: Running C:\windows\syswow64\cscript.exe 2023-02-10 03:11:09.8: Arguments: '//NoLogo "C:\Users\Public\Documents\ACP Config\Scheduler\ShutdownObs.js"' 2023-02-10 03:11:09.9: Results look OK, the tool returned this text: 2023-02-10 03:11:09.9: '' 2023-02-10 03:11:10.1: Run statistics: 2023-02-10 03:11:10.1: Observations: 272 2023-02-10 03:11:10.1: Considered: 13 2023-02-10 03:11:10.1: Completed: 0 2023-02-10 03:11:10.1: Skipped: 0 2023-02-10 03:11:10.1: Never Eligible: 259 2023-02-10 03:11:10.1: Failed: 13 2023-02-10 03:11:10.1: Shutter-Open efficiency: 44.50% 2023-02-10 03:11:10.1: Overall Efficiency: 85.62%