Log opened at Tue, Jan 04 2022 05:41:56 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 8.3.2 Part of ACP Expert Release 8.3 Full license: Arne Henden 2022-01-04 05:41:56.5: REAL TIME internal clock initialized at 04-Jan-2022 05:41:56 UTC 2022-01-04 05:41:56.5: Dispatcher started at 04-Jan-2022 05:41:56 UTC 2022-01-04 05:41:56.7: Loaded Constraint plugin AirMass 2022-01-04 05:41:56.7: Loaded Constraint plugin AirmassRange 2022-01-04 05:41:56.7: Loaded Constraint plugin Horizon 2022-01-04 05:41:56.7: Loaded Constraint plugin HourAngle 2022-01-04 05:41:56.7: Loaded Constraint plugin MoonAvoid 2022-01-04 05:41:56.7: Loaded Constraint plugin MoonDown 2022-01-04 05:41:56.8: Loaded Constraint plugin SkyCondition 2022-01-04 05:41:56.8: Loaded Constraint plugin TimeRange 2022-01-04 05:41:57.6: 173 plans are now pending. 2022-01-04 05:41:57.7: Attach ACP sequencer 2022-01-04 05:42:04.0: ++ Weather Safe ++ 2022-01-04 05:42:04.5: ==== Dispatcher is running in NORMAL (NIGHT) mode ==== 2022-01-04 05:42:04.5: Sequencer does sky flats 2022-01-04 05:42:06.0: HTTP command listener failed to start: Access is denied 2022-01-04 05:42:06.0: If this is Windows 8-10, you will need to add permission (ACL) to listen on port 9123. 2022-01-04 05:42:06.0: See Scheduler Help > Configuring the Program > Noteworthy Configuration Options, at the bottom. 2022-01-04 05:42:17.4: ++ Observatory Startup ++ 2022-01-04 05:42:17.4: Weather safety is now disabled 2022-01-04 05:42:17.4: Start ACP Sequencer's StartupObs script 2022-01-04 05:43:00.5: Weather safety is re-enabled 2022-01-04 05:43:00.6: Weather safety is now disabled 2022-01-04 05:43:00.6: Open the observatory dome/roof 2022-01-04 05:44:01.3: Weather safety is re-enabled 2022-01-04 05:44:01.3: Observatory startup succeeded, and dome opened successfully 2022-01-04 05:44:01.3: ++ Auto Focus ++ 2022-01-04 05:44:01.4: Doing initial autofocus. 2022-01-04 05:44:01.4: Start special ACP AutoFocus script for scheduler 2022-01-04 05:51:41.3: Next periodic autofocus ASAP after 3600sec. 04-Jan-2022 06:51:28 UTC 2022-01-04 05:51:51.8: Dispatcher cycle time: 10.5 sec. 2022-01-04 05:51:51.8: Acquire data for Observation B0133+47... 2022-01-04 05:51:51.8: (belongs to Project AAVSO_survey_HQ_AUTO_ver2706, Plan B0133+47) 2022-01-04 05:51:51.9: Send Observation B0133+47 to ACP Sequencer 2022-01-04 05:56:37.0: **DISPATCHER INTERRUPT LEVEL 1 RECEIVED** 2022-01-04 05:59:19.9: ** ACP script "AcquireScheduler" failed: 2022-01-04 05:59:19.9: **Script Error (Tracking has been stopped)** Source: ACP Observatory Control Software Message: Location: line 1885 column 5. 2022-01-04 05:59:19.9: RUN FAILED: Scheduler was stopped during run 2022-01-04 05:59:20.0: ACP data acquisition failed for Observation B0133+47. 2022-01-04 05:59:20.0: (Observation B0133+47 interrupted by operator or system.) 2022-01-04 06:01:00.2: **EXCEPTION IN SCHEDULER: 2022-01-04 06:01:00.2: The callee (server [not server application]) is not available and disappeared; all connections are invalid. The call may have executed. (Exception from HRESULT: 0x80010007 (RPC_E_SERVER_DIED)) 2022-01-04 06:01:00.5: Traceback: at ACP.UtilClass.get_Scheduler() at DC3.Scheduler.ACPSequencer.set_DispatcherStatus(StatusValue value) at DC3.Scheduler.Engine.set_Status(StatusValue value) at DC3.Scheduler.Engine.Run() 2022-01-04 06:01:00.5: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2022-01-04 06:01:00.5: The callee (server [not server application]) is not available and disappeared; all connections are invalid. The call may have executed. (Exception from HRESULT: 0x80010007 (RPC_E_SERVER_DIED)) 2022-01-04 06:01:00.6: No operator intervention command tool specified