Log opened at Tue, Jan 04 2022 03:06:38 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 8.3.2 Part of ACP Expert Release 8.3 Full license: Arne Henden 2022-01-04 03:06:38.7: REAL TIME internal clock initialized at 04-Jan-2022 03:06:38 UTC 2022-01-04 03:06:38.7: Dispatcher started at 04-Jan-2022 03:06:38 UTC 2022-01-04 03:06:38.8: Loaded Constraint plugin AirMass 2022-01-04 03:06:38.8: Loaded Constraint plugin AirmassRange 2022-01-04 03:06:38.8: Loaded Constraint plugin Horizon 2022-01-04 03:06:38.8: Loaded Constraint plugin HourAngle 2022-01-04 03:06:38.8: Loaded Constraint plugin MoonAvoid 2022-01-04 03:06:38.8: Loaded Constraint plugin MoonDown 2022-01-04 03:06:38.8: Loaded Constraint plugin SkyCondition 2022-01-04 03:06:38.8: Loaded Constraint plugin TimeRange 2022-01-04 03:06:39.7: 185 plans are now pending. 2022-01-04 03:06:39.8: Attach ACP sequencer 2022-01-04 03:06:46.0: There is no controllable dome or roof. 2022-01-04 03:06:46.1: ++ Weather Safe ++ 2022-01-04 03:06:46.6: ==== Dispatcher is running in NORMAL (NIGHT) mode ==== 2022-01-04 03:06:46.7: Sequencer does sky flats 2022-01-04 03:06:48.2: HTTP command listener failed to start: Access is denied 2022-01-04 03:06:48.2: If this is Windows 8-10, you will need to add permission (ACL) to listen on port 9123. 2022-01-04 03:06:48.2: See Scheduler Help > Configuring the Program > Noteworthy Configuration Options, at the bottom. 2022-01-04 03:06:56.0: ++ Observatory Startup ++ 2022-01-04 03:06:56.0: Weather safety is now disabled 2022-01-04 03:06:56.0: Start ACP Sequencer's StartupObs script 2022-01-04 03:08:12.1: Weather safety is re-enabled 2022-01-04 03:08:12.1: Weather safety is now disabled 2022-01-04 03:08:12.1: Open the observatory dome/roof 2022-01-04 03:09:12.9: Weather safety is re-enabled 2022-01-04 03:09:12.9: Observatory startup succeeded, and dome opened successfully 2022-01-04 03:09:12.9: ++ Auto Focus ++ 2022-01-04 03:09:12.9: Doing initial autofocus. 2022-01-04 03:09:12.9: Start special ACP AutoFocus script for scheduler 2022-01-04 03:17:00.3: Next periodic autofocus ASAP after 3600sec. 04-Jan-2022 04:16:42 UTC 2022-01-04 03:17:10.8: Dispatcher cycle time: 10.5 sec. 2022-01-04 03:17:10.8: Acquire data for Observation EE_Cep... 2022-01-04 03:17:10.8: (belongs to Project AAVSO_P124_Staels_AUTO_ver2706, Plan EE_Cep) 2022-01-04 03:17:10.9: Send Observation EE_Cep to ACP Sequencer 2022-01-04 03:30:46.9: Acquisition time: 816.0205041 sec. 2022-01-04 03:30:46.9: Data for Observation EE_Cep of Plan EE_Cep acquired successfully. 2022-01-04 03:30:47.0: Plan EE_Cep completed successfully. 2022-01-04 03:30:47.0: Image Efficiency: 21.8% 2022-01-04 03:30:47.0: Cycle Efficiency: 98.7% 2022-01-04 03:30:47.1: **EXCEPTION IN SCHEDULER: 2022-01-04 03:30:47.1: DOME FAILURE: Dome reports shutter error status 2022-01-04 03:30:47.2: Traceback: at DC3.Scheduler.ACPSequencer.get_DomeOpen() at DC3.Scheduler.Engine.DoStartupIf(Boolean openDome) at DC3.Scheduler.Engine.Run() 2022-01-04 03:30:47.3: Weather safety is now disabled 2022-01-04 03:30:47.3: Weather safety is re-enabled 2022-01-04 03:30:47.3: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2022-01-04 03:30:47.3: DOME FAILURE: Dome reports shutter error status when asked to close. 2022-01-04 03:30:47.4: No operator intervention command tool specified 2022-01-04 03:30:49.3: Run statistics: 2022-01-04 03:30:49.3: Observations: 205 2022-01-04 03:30:49.3: Considered: 1 2022-01-04 03:30:49.3: Completed: 0 2022-01-04 03:30:49.3: Skipped: 0 2022-01-04 03:30:49.3: Never Eligible: 204 2022-01-04 03:30:49.3: Failed: 1 2022-01-04 03:30:49.3: Shutter-Open efficiency: 21.77% 2022-01-04 03:30:49.3: Overall Efficiency: 98.71% 2022-01-04 03:30:49.3: Release ACP sequencer Log closed at Tue, Jan 04 2022 03:30:52 UTC (actual time)