Log opened at Thu, Dec 16 2021 00:08:06 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 8.3.2 Part of ACP Expert Release 8.3 Full license: Arne Henden 2021-12-16 00:08:06.6: REAL TIME internal clock initialized at 16-Dec-2021 00:08:06 UTC 2021-12-16 00:08:06.6: Dispatcher started at 16-Dec-2021 00:08:06 UTC 2021-12-16 00:08:06.7: Loaded Constraint plugin AirMass 2021-12-16 00:08:06.7: Loaded Constraint plugin AirmassRange 2021-12-16 00:08:06.7: Loaded Constraint plugin Horizon 2021-12-16 00:08:06.7: Loaded Constraint plugin HourAngle 2021-12-16 00:08:06.7: Loaded Constraint plugin MoonAvoid 2021-12-16 00:08:06.7: Loaded Constraint plugin MoonDown 2021-12-16 00:08:06.7: Loaded Constraint plugin SkyCondition 2021-12-16 00:08:06.7: Loaded Constraint plugin TimeRange 2021-12-16 00:08:07.6: 180 plans are now pending. 2021-12-16 00:08:07.7: Attach ACP sequencer 2021-12-16 00:08:13.9: There is no controllable dome or roof. 2021-12-16 00:08:14.0: ++ Weather Safe ++ 2021-12-16 00:08:14.6: ==== Dispatcher is running in NORMAL (NIGHT) mode ==== 2021-12-16 00:08:14.6: Sequencer does sky flats 2021-12-16 00:08:17.3: HTTP command listener failed to start: Access is denied 2021-12-16 00:08:17.3: If this is Windows 8-10, you will need to add permission (ACL) to listen on port 9123. 2021-12-16 00:08:17.3: See Scheduler Help > Configuring the Program > Noteworthy Configuration Options, at the bottom. 2021-12-16 00:09:03.4: ++ Observatory Startup ++ 2021-12-16 00:09:03.4: Weather safety is now disabled 2021-12-16 00:09:03.4: Start ACP Sequencer's StartupObs script 2021-12-16 00:09:55.0: Weather safety is re-enabled 2021-12-16 00:09:55.0: Weather safety is now disabled 2021-12-16 00:09:55.0: Open the observatory dome/roof 2021-12-16 00:10:55.8: Weather safety is re-enabled 2021-12-16 00:10:55.8: Observatory startup succeeded, and dome opened successfully 2021-12-16 00:10:55.8: ++ Dusk Sky Flats ++ 2021-12-16 00:10:55.8: Start ACP AutoFlat script for Dusk flats 2021-12-16 00:24:04.0: ** ACP script "AutoFlat" failed: 2021-12-16 00:24:04.0: **Script Error** Source: ACP Observatory Control Software Message: The script was interrupted before completion. Location: line 955 column 13. 2021-12-16 00:25:07.0: **DISPATCHER INTERRUPT LEVEL 1 RECEIVED** 2021-12-16 00:25:11.5: ++ Observatory Startup ++ 2021-12-16 00:25:11.5: Weather safety is now disabled 2021-12-16 00:25:11.5: Start ACP Sequencer's StartupObs script 2021-12-16 00:26:03.3: Weather safety is re-enabled 2021-12-16 00:26:03.3: Observatory startup succeeded 2021-12-16 00:26:03.3: ++ Dusk Sky Flats ++ 2021-12-16 00:26:03.4: Start ACP AutoFlat script for Dusk flats 2021-12-16 00:46:16.1: ++ Auto Focus ++ 2021-12-16 00:46:16.1: Doing initial autofocus. 2021-12-16 00:46:16.1: Start special ACP AutoFocus script for scheduler 2021-12-16 00:53:28.8: Next periodic autofocus ASAP after 3600sec. 16-Dec-2021 01:53:13 UTC 2021-12-16 00:53:33.4: Plan EE_Cep has Monitor Mode. Time to resubmit it. 2021-12-16 00:53:33.4: Plan EE_Cep has Monitor Mode. Time to resubmit it. 2021-12-16 00:53:33.4: Plan GZ_Cet has Monitor Mode. Time to resubmit it. 2021-12-16 00:53:33.4: Plan V630_Cas has Monitor Mode. Time to resubmit it. 2021-12-16 00:53:37.4: Dispatcher cycle time: 8.6 sec. 2021-12-16 00:53:37.4: Acquire data for Observation V1674_Her... 2021-12-16 00:53:37.4: (belongs to Project AAVSO_MISC_CWT_AUTO_ver2730, Plan V1674_Her) 2021-12-16 00:53:37.4: Doing 5 sets 2021-12-16 00:53:37.4: ***Running Plan V1674_Her (best efforts) completed early: 2021-12-16 00:53:37.4: Obs V1674_Her would not meet strict constraints 2021-12-16 00:53:37.4: Acquisition time: 0 sec. 2021-12-16 00:53:37.4: Data for Observation V1674_Her of Plan V1674_Her acquired successfully. 2021-12-16 00:53:37.5: Plan V1674_Her completed successfully. 2021-12-16 00:53:37.5: Image Efficiency: 0.0% 2021-12-16 00:53:37.5: Cycle Efficiency: 0.0% 2021-12-16 00:53:40.3: Dispatcher cycle time: 2.7 sec. 2021-12-16 00:53:40.3: Acquire data for Observation IX_Dra... 2021-12-16 00:53:40.3: (belongs to Project AAVSO_P153_SFY_AUTO_ver2706, Plan IX_Dra) 2021-12-16 00:53:40.4: Send Observation IX_Dra to ACP Sequencer 2021-12-16 01:17:58.5: Acquisition time: 1458.1172785 sec. 2021-12-16 01:17:58.5: Data for Observation IX_Dra of Plan IX_Dra acquired successfully. 2021-12-16 01:17:58.5: Plan IX_Dra completed successfully. 2021-12-16 01:17:58.6: Image Efficiency: 82.1% 2021-12-16 01:17:58.6: Cycle Efficiency: 99.8% 2021-12-16 01:18:00.8: Dispatcher cycle time: 2.1 sec. 2021-12-16 01:18:00.8: Acquire data for Observation MV_Lyr... 2021-12-16 01:18:00.8: (belongs to Project AAVSO_P233_DKS_AUTO_ver2623, Plan MV_Lyr) 2021-12-16 01:18:00.8: Send Observation MV_Lyr to ACP Sequencer 2021-12-16 01:38:59.2: ACP data acquisition failed for Observation MV_Lyr. 2021-12-16 01:38:59.2: (Observation MV_Lyr interrupted by acquisition process failure.) 2021-12-16 01:39:01.5: Dispatcher cycle time: 2.0 sec. 2021-12-16 01:39:01.5: Acquire data for Observation CG_Dra... 2021-12-16 01:39:01.5: (belongs to Project AAVSO_P211_BENS_AUTO_ver2706, Plan CG_Dra) 2021-12-16 01:39:01.5: Send Observation CG_Dra to ACP Sequencer 2021-12-16 01:53:58.5: Acquisition time: 896.9665314 sec. 2021-12-16 01:53:58.5: Data for Observation CG_Dra of Plan CG_Dra acquired successfully. 2021-12-16 01:53:58.6: Plan CG_Dra completed successfully. 2021-12-16 01:53:58.6: Image Efficiency: 80.1% 2021-12-16 01:53:58.6: Cycle Efficiency: 99.8% 2021-12-16 01:53:58.8: **EXCEPTION IN SCHEDULER: 2021-12-16 01:53:58.8: DOME FAILURE: Dome reports shutter error status 2021-12-16 01:53:59.9: Traceback: at DC3.Scheduler.ACPSequencer.get_DomeOpen() at DC3.Scheduler.Engine.DoStartupIf(Boolean openDome) at DC3.Scheduler.Engine.Run() 2021-12-16 01:53:59.9: Weather safety is now disabled 2021-12-16 01:53:59.9: Weather safety is re-enabled 2021-12-16 01:53:59.9: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2021-12-16 01:53:59.9: DOME FAILURE: Dome reports shutter error status when asked to close. 2021-12-16 01:54:00.0: No operator intervention command tool specified 2021-12-16 01:54:01.1: Run statistics: 2021-12-16 01:54:01.1: Observations: 202 2021-12-16 01:54:01.1: Considered: 2 2021-12-16 01:54:01.1: Completed: 0 2021-12-16 01:54:01.1: Skipped: 0 2021-12-16 01:54:01.1: Never Eligible: 200 2021-12-16 01:54:01.1: Failed: 2 2021-12-16 01:54:01.1: Shutter-Open efficiency: 52.90% 2021-12-16 01:54:01.1: Overall Efficiency: 99.56% 2021-12-16 01:54:01.1: Release ACP sequencer Log closed at Thu, Dec 16 2021 01:54:03 UTC (actual time)