Log opened at Thu, Nov 18 2021 22:54:45 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 8.3.2 Part of ACP Expert Release 8.3 Full license: Arne Henden 2021-11-18 22:54:45.7: REAL TIME internal clock initialized at 18-Nov-2021 22:54:45 UTC 2021-11-18 22:54:45.7: Dispatcher started at 18-Nov-2021 22:54:45 UTC 2021-11-18 22:54:48.5: Loaded Constraint plugin AirMass 2021-11-18 22:54:48.5: Loaded Constraint plugin AirmassRange 2021-11-18 22:54:48.6: Loaded Constraint plugin Horizon 2021-11-18 22:54:48.6: Loaded Constraint plugin HourAngle 2021-11-18 22:54:48.8: Loaded Constraint plugin MoonAvoid 2021-11-18 22:54:49.3: Loaded Constraint plugin MoonDown 2021-11-18 22:54:49.4: Loaded Constraint plugin SkyCondition 2021-11-18 22:54:49.5: Loaded Constraint plugin TimeRange 2021-11-18 22:54:50.5: 2 plans are now pending. 2021-11-18 22:54:50.6: Attach ACP sequencer 2021-11-18 22:54:58.5: There is no controllable dome or roof. 2021-11-18 22:54:59.0: ==== Dispatcher is running in NORMAL (NIGHT) mode ==== 2021-11-18 22:54:59.1: Sequencer does sky flats 2021-11-18 22:55:00.3: ConnectWeather() failed: 2021-11-18 22:55:00.3: ACP.BoltwoodFile -> Weather data file is stale (> 60 sec old) 2021-11-18 22:55:01.3: HTTP command listener failed to start: Access is denied 2021-11-18 22:55:01.3: If this is Windows 8-10, you will need to add permission (ACL) to listen on port 9123. 2021-11-18 22:55:01.3: See Scheduler Help > Configuring the Program > Noteworthy Configuration Options, at the bottom. 2021-11-18 22:56:20.4: Weather successfully connected. Wait for valid data... 2021-11-18 23:17:39.8: ++ Weather Safe ++ 2021-11-19 00:01:01.8: ++ Observatory Startup ++ 2021-11-19 00:01:01.8: Weather safety is now disabled 2021-11-19 00:01:01.8: Start ACP Sequencer's StartupObs script 2021-11-19 00:01:36.1: Weather safety is re-enabled 2021-11-19 00:01:36.1: Weather safety is now disabled 2021-11-19 00:01:36.1: Open the observatory dome/roof 2021-11-19 00:02:36.8: Weather safety is re-enabled 2021-11-19 00:02:36.8: Observatory startup succeeded, and dome opened successfully 2021-11-19 00:02:36.8: ++ Dusk Sky Flats ++ 2021-11-19 00:02:36.9: Start ACP AutoFlat script for Dusk flats 2021-11-19 00:20:30.0: **DISPATCHER INTERRUPT LEVEL 1 RECEIVED** 2021-11-19 00:21:05.2: ++ Observatory Startup ++ 2021-11-19 00:21:05.2: Weather safety is now disabled 2021-11-19 00:21:05.2: Start ACP Sequencer's StartupObs script 2021-11-19 00:21:22.7: Weather safety is re-enabled 2021-11-19 00:21:22.7: Observatory startup succeeded 2021-11-19 00:21:22.7: ++ Dusk Sky Flats ++ 2021-11-19 00:21:22.7: Start ACP AutoFlat script for Dusk flats 2021-11-19 02:06:52.4: ** ACP script "AutoFlat" failed: 2021-11-19 02:06:52.4: **Script Error (Tracking has been stopped)** Source: Microsoft VBScript runtime error Message: The remote server machine does not exist or is unavailable Probably an error in the flat plan Location: line 961 column 17. 2021-11-19 02:06:52.4: ++ Auto Focus ++ 2021-11-19 02:06:52.5: Doing initial autofocus. 2021-11-19 02:06:52.5: Start special ACP AutoFocus script for scheduler 2021-11-19 02:07:09.9: ** ACP script "AutoFocusScheduler" failed: 2021-11-19 02:07:09.9: **Script Error (Tracking has been stopped)** Source: Microsoft VBScript runtime error Message: The remote server machine does not exist or is unavailable: 'Camera.LinkEnabled' Location: line 42 column 5. 2021-11-19 02:07:09.9: ** Autofocus failed (n=1), will retry ASAP after 0 min. 2021-11-19 02:07:15.5: ++ Auto Focus ++ 2021-11-19 02:07:15.5: Doing periodic autofocus. 2021-11-19 02:07:15.5: Start special ACP AutoFocus script for scheduler 2021-11-19 02:07:30.6: ** ACP script "AutoFocusScheduler" failed: 2021-11-19 02:07:30.6: **Script Error (Tracking has been stopped)** Source: Microsoft VBScript runtime error Message: The remote server machine does not exist or is unavailable: 'Camera.LinkEnabled' Location: line 42 column 5. 2021-11-19 02:07:30.6: ** Autofocus failed (n=2), will retry ASAP after 5 min. 2021-11-19 02:12:31.2: ++ Auto Focus ++ 2021-11-19 02:12:31.4: Doing periodic autofocus. 2021-11-19 02:12:31.4: Start special ACP AutoFocus script for scheduler 2021-11-19 02:12:53.2: ** ACP script "AutoFocusScheduler" failed: 2021-11-19 02:12:53.2: **Script Error (Tracking has been stopped)** Source: Microsoft VBScript runtime error Message: The remote server machine does not exist or is unavailable: 'Camera.LinkEnabled' Location: line 42 column 5. 2021-11-19 02:12:53.2: ** Autofocus failed (n=3), will retry ASAP after 10 min. 2021-11-19 02:13:52.1: -- Weather Unsafe -- 2021-11-19 02:48:05.2: **EXCEPTION IN SCHEDULER: 2021-11-19 02:48:05.2: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA) 2021-11-19 02:48:05.4: Traceback: at ACP.UtilClass.get_Scheduler() at DC3.Scheduler.ACPSequencer.set_DispatcherStatus(StatusValue value) at DC3.Scheduler.Engine.set_Status(StatusValue value) at DC3.Scheduler.Engine.Run() 2021-11-19 02:48:05.4: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2021-11-19 02:48:05.4: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA) 2021-11-19 02:48:05.4: No operator intervention command tool specified