Log opened at Mon, Nov 15 2021 00:21:06 UTC (actual time) Current log level is Normal ACP Expert Scheduler Engine Version 8.3.2 Part of ACP Expert Release 8.3 Full license: Arne Henden 2021-11-15 00:21:06.3: REAL TIME internal clock initialized at 15-Nov-2021 00:21:06 UTC 2021-11-15 00:21:06.3: Dispatcher started at 15-Nov-2021 00:21:06 UTC 2021-11-15 00:21:06.4: Loaded Constraint plugin AirMass 2021-11-15 00:21:06.4: Loaded Constraint plugin AirmassRange 2021-11-15 00:21:06.4: Loaded Constraint plugin Horizon 2021-11-15 00:21:06.4: Loaded Constraint plugin HourAngle 2021-11-15 00:21:06.4: Loaded Constraint plugin MoonAvoid 2021-11-15 00:21:06.4: Loaded Constraint plugin MoonDown 2021-11-15 00:21:06.4: Loaded Constraint plugin SkyCondition 2021-11-15 00:21:06.5: Loaded Constraint plugin TimeRange 2021-11-15 00:21:07.3: 3 plans are now pending. 2021-11-15 00:21:07.3: Attach ACP sequencer 2021-11-15 00:21:13.5: There is no controllable dome or roof. 2021-11-15 00:21:13.8: Weather successfully connected. Wait for valid data... 2021-11-15 00:21:14.3: ==== Dispatcher is running in NORMAL (NIGHT) mode ==== 2021-11-15 00:21:14.3: Sequencer does sky flats 2021-11-15 00:21:18.8: ++ Weather Safe ++ 2021-11-15 00:21:18.8: HTTP command listener failed to start: Access is denied 2021-11-15 00:21:18.8: If this is Windows 8-10, you will need to add permission (ACL) to listen on port 9123. 2021-11-15 00:21:18.8: See Scheduler Help > Configuring the Program > Noteworthy Configuration Options, at the bottom. 2021-11-15 00:21:24.9: ++ Observatory Startup ++ 2021-11-15 00:21:24.9: Weather safety is now disabled 2021-11-15 00:21:24.9: Start ACP Sequencer's StartupObs script 2021-11-15 00:22:02.9: Weather safety is re-enabled 2021-11-15 00:22:02.9: Observatory startup succeeded 2021-11-15 00:22:02.9: ++ Dusk Sky Flats ++ 2021-11-15 00:22:02.9: Start ACP AutoFlat script for Dusk flats 2021-11-15 00:32:45.7: **EXCEPTION IN SCHEDULER: 2021-11-15 00:32:45.7: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA) 2021-11-15 00:32:45.9: Traceback: at System.RuntimeType.InvokeDispMethod(String name, BindingFlags invokeAttr, Object target, Object[] args, Boolean[] byrefModifiers, Int32 culture, String[] namedParameters) at System.RuntimeType.InvokeMember(String name, BindingFlags bindingFlags, Binder binder, Object target, Object[] providedArgs, ParameterModifier[] modifiers, CultureInfo culture, String[] namedParams) at System.Type.InvokeMember(String name, BindingFlags invokeAttr, Binder binder, Object target, Object[] args) at DC3.Scheduler.ACPSequencer.RunScript(String scrPath, String param) at DC3.Scheduler.ACPSequencer.DoAutoFlats(Boolean isDawn) at DC3.Scheduler.Engine.Run() 2021-11-15 00:32:45.9: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2021-11-15 00:32:45.9: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA) 2021-11-15 00:32:46.0: No operator intervention command tool specified