Log opened at Tue, Mar 16 2021 12:21:46 UTC (actual time) Current log level is Debug ACP Expert Scheduler version 8.2.3 Full license: Arne Henden 2021-03-16 12:21:47.2: ++ Observatory Startup ++ 2021-03-16 12:21:47.2: Start ACP Sequencer's StartupObs script 2021-03-16 12:21:47.3: ACP.RunScript(StartupObs, ): 2021-03-16 12:21:47.3: No script is loaded. ACP is definitely idle 2021-03-16 12:21:47.3: In start loop, i = 0 2021-03-16 12:21:47.3: Console is now idle 2021-03-16 12:21:47.7: Loaded C:\Users\Public\Documents\ACP Config\Scheduler\StartupObs.js successfully 2021-03-16 12:21:47.7: Script started successfully 2021-03-16 12:21:57.7: Sequencer is now active 2021-03-16 12:22:38.3: Sequencer is no longer active 2021-03-16 12:22:38.3: Open the observatory dome/roof 2021-03-16 12:23:39.1: Observatory startup succeeded, and dome opened successfully 2021-03-16 12:23:39.1: ++ Auto Focus ++ 2021-03-16 12:23:39.1: Doing initial autofocus. 2021-03-16 12:23:39.1: Start special ACP AutoFocus script for scheduler 2021-03-16 12:23:39.1: ACP.RunScript(AutoFocusScheduler, ): 2021-03-16 12:23:39.1: Script StartupObs is loaded, and 2021-03-16 12:23:39.1: the console is idle. 2021-03-16 12:23:39.1: In start loop, i = 0 2021-03-16 12:23:39.1: Console is now idle 2021-03-16 12:23:39.1: Loaded C:\Program Files (x86)\ACP Scheduler\AutoFocusScheduler.vbs successfully 2021-03-16 12:23:39.1: Script started successfully 2021-03-16 12:23:49.2: Sequencer is now active 2021-03-16 12:29:33.9: Sequencer is no longer active 2021-03-16 12:29:33.9: Next periodic autofocus ASAP after 3600sec. 16-Mar-2021 13:29:20 UTC 2021-03-16 12:34:29.7: ++ Dawn Flats ++ 2021-03-16 12:34:29.8: Start ACP AutoFlat script for Dawn flats 2021-03-16 12:34:29.8: ACP.RunScript(AutoFlat, C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt): 2021-03-16 12:34:29.8: Script AutoFocusScheduler is loaded, and 2021-03-16 12:34:29.8: the console is idle. 2021-03-16 12:34:29.8: In start loop, i = 0 2021-03-16 12:34:29.8: Console is now idle 2021-03-16 12:34:30.0: Loaded C:\Program Files (x86)\ACP Obs Control\Scripts\AutoFlat.vbs successfully 2021-03-16 12:34:30.1: Set parameter "C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt" successfully 2021-03-16 12:34:30.1: Script started successfully 2021-03-16 12:34:40.1: Sequencer is now active 2021-03-16 12:35:55.5: Sequencer is no longer active 2021-03-16 12:36:06.7: -- Observatory Shutdown -- 2021-03-16 12:36:07.0: Start ACP Sequencer's ShutdownObs script 2021-03-16 12:36:07.0: ACP.RunScript(ShutdownObs, ): 2021-03-16 12:36:07.0: Script AutoFlat is loaded, and 2021-03-16 12:36:07.0: the console is idle. 2021-03-16 12:36:07.0: In start loop, i = 0 2021-03-16 12:36:07.0: Console is now idle 2021-03-16 12:36:07.6: Loaded C:\Users\Public\Documents\ACP Config\Scheduler\ShutdownObs.js successfully 2021-03-16 12:36:07.6: Script started successfully 2021-03-16 12:36:17.6: Sequencer is now active 2021-03-16 12:38:03.1: Sequencer is no longer active 2021-03-16 12:54:49.8: -- Weather Unsafe -- 2021-03-16 13:15:47.9: Start ACP AutoFlat script for Dawn flats 2021-03-16 13:15:47.9: ACP.RunScript(AutoFlat, C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt): 2021-03-16 13:15:47.9: Script ACP-Weather is loaded, and 2021-03-16 13:15:47.9: the console is idle. 2021-03-16 13:15:47.9: In start loop, i = 0 2021-03-16 13:15:47.9: Console is now idle 2021-03-16 13:15:47.9: Loaded C:\Program Files (x86)\ACP Obs Control\Scripts\AutoFlat.vbs successfully 2021-03-16 13:15:47.9: Set parameter "C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt" successfully 2021-03-16 13:15:47.9: Script started successfully 2021-03-16 13:15:58.0: Sequencer is now active 2021-03-16 13:16:03.2: Sequencer is no longer active 2021-03-16 13:16:03.2: ** ACP script "AutoFlat" failed: 2021-03-16 13:16:03.2: **Script Error (Tracking has been stopped)** Source: ACP.AcquireSupport Message: **The weather is unsafe. Cannot continue. Location: line 710 column 9. **Script Error** ACP script error 0x80073B01 from ThinScript.ActiveScript: The resource loader cache doesn't have loaded MUI entry.. 2021-03-16 15:58:05.4: Start ACP AutoFlat script for Dawn flats 2021-03-16 15:58:05.4: ACP.RunScript(AutoFlat, C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt): 2021-03-16 15:58:05.4: Script AutoFlat is loaded, and 2021-03-16 15:58:05.4: the console is idle. 2021-03-16 15:58:05.4: In start loop, i = 0 2021-03-16 15:58:05.4: Console is now idle 2021-03-16 15:58:05.4: Loaded C:\Program Files (x86)\ACP Obs Control\Scripts\AutoFlat.vbs successfully 2021-03-16 15:58:05.4: Set parameter "C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt" successfully 2021-03-16 15:58:05.4: Script started successfully 2021-03-16 15:58:15.4: Sequencer is now active 2021-03-16 15:58:20.8: Sequencer is no longer active 2021-03-16 15:58:20.8: ** ACP script "AutoFlat" failed: 2021-03-16 15:58:20.8: **Script Error (Tracking has been stopped)** Source: ACP.AcquireSupport Message: **The weather is unsafe. Cannot continue. Location: line 710 column 9. **Script Error** ACP script error 0x80073B01 from ThinScript.ActiveScript: The resource loader cache doesn't have loaded MUI entry.. 2021-03-16 16:08:27.7: Start ACP AutoFlat script for Dawn flats 2021-03-16 16:08:27.7: ACP.RunScript(AutoFlat, C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt): 2021-03-16 16:08:27.7: Script AutoFlat is loaded, and 2021-03-16 16:08:27.7: the console is idle. 2021-03-16 16:08:27.7: In start loop, i = 0 2021-03-16 16:08:27.7: Console is now idle 2021-03-16 16:08:27.8: Loaded C:\Program Files (x86)\ACP Obs Control\Scripts\AutoFlat.vbs successfully 2021-03-16 16:08:27.8: Set parameter "C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt" successfully 2021-03-16 16:08:27.8: Script started successfully 2021-03-16 16:08:37.8: Sequencer is now active 2021-03-16 16:08:42.9: Sequencer is no longer active 2021-03-16 16:08:42.9: ** ACP script "AutoFlat" failed: 2021-03-16 16:08:42.9: **Script Error (Tracking has been stopped)** Source: ACP.AcquireSupport Message: **The weather is unsafe. Cannot continue. Location: line 710 column 9. **Script Error** ACP script error 0x80073B01 from ThinScript.ActiveScript: The resource loader cache doesn't have loaded MUI entry.. 2021-03-16 16:10:45.9: Weather successfully connected. Wait for valid data... 2021-03-16 16:10:51.5: Start ACP AutoFlat script for Dawn flats 2021-03-16 16:10:51.5: ACP.RunScript(AutoFlat, C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt): 2021-03-16 16:10:51.5: Script AutoFlat is loaded, and 2021-03-16 16:10:51.5: the console is idle. 2021-03-16 16:10:51.5: In start loop, i = 0 2021-03-16 16:10:51.5: Console is now idle 2021-03-16 16:10:51.5: Loaded C:\Program Files (x86)\ACP Obs Control\Scripts\AutoFlat.vbs successfully 2021-03-16 16:10:51.6: Set parameter "C:\Users\admin\Documents\ACP Astronomy\Plans\SchedulerDawnFlats.txt" successfully 2021-03-16 16:10:51.6: Script started successfully 2021-03-16 16:11:01.6: Sequencer is now active 2021-03-16 16:11:06.7: Sequencer is no longer active 2021-03-16 16:11:06.7: ** ACP script "AutoFlat" failed: 2021-03-16 16:11:06.7: **Script Error (Tracking has been stopped)** Source: ACP.AcquireSupport Message: **The weather is unsafe. Cannot continue. Location: line 710 column 9. **Script Error** ACP script error 0x80073B01 from ThinScript.ActiveScript: The resource loader cache doesn't have loaded MUI entry.. 2021-03-16 16:15:21.3: Weather successfully connected. Wait for valid data... 2021-03-17 03:31:09.0: Weather successfully connected. Wait for valid data... 2021-03-17 03:31:16.3: **EXCEPTION IN SCHEDULER: 2021-03-17 03:31:16.3: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA) 2021-03-17 03:31:18.6: Traceback: at ACP.UtilClass.get_Scheduler() at DC3.Scheduler.ACPSequencer.set_DispatcherStatus(StatusValue value) at DC3.Scheduler.Engine.set_Status(StatusValue value) at DC3.Scheduler.Engine.Run() 2021-03-17 03:31:18.6: DOME/ROOF FAILURE: In addition, attempting to close your dome/roof this error occurred: 2021-03-17 03:31:18.6: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA)