ACP console log opened 22-Jan-2023 01:12:52 UTC This is ACP version 9.0 (build 4, ACP 9 Production Release) Licensed to Arne Henden 01:12:52 Starting support programs as needed 01:12:52 Starting ClarityII.exe 01:13:07 OK 01:13:07 Connect to Clarity and wait for data 01:13:22 OK 01:13:27 Connect ACP to the telescope, will auto-home if needed 01:13:35 OK 01:13:41 Connect ACP to the camera 01:13:41 OK 01:13:41 Temperature set by file: C:\\Users\\Public\\Documents\\ACP Config\\Scheduler\\temperature.txt 01:13:41 Chill cooler to -12 01:13:46 Running svn... 01:13:47 ...OK 01:13:47 Running svn... 01:13:48 ...OK 01:13:48 Running svn... 01:13:49 ...OK 01:13:49 Running cscript... 01:13:51 AAVSO_DCEP_HQA_AUTO.csv 01:13:52 imported: C:\Data\Plans\AAVSO_DCEP_HQA_AUTO.csv.xml 01:13:53 deleted AAVSO_DCEP_HQA_AUTO_ver3411 01:13:54 AAVSO_HGUA_Miras_Manual.csv 01:13:54 MANUAL file; not imported 01:13:55 AAVSO_Kepler_HQA_AUTO.csv 01:13:55 not newer 01:13:55 AAVSO_Landolt1_HQA_MANUAL.csv 01:13:56 MANUAL file; not imported 01:13:56 AAVSO_Landolt2_HQA_MANUAL.csv 01:13:57 line 10: maxX is 2.5 . This is greater than the warning level of 2 01:13:57 line 11: maxX is 2.5 . This is greater than the warning level of 2 01:13:58 And there are others above the warning level.... 01:13:58 MANUAL file; not imported 01:13:59 AAVSO_MISC_BBRD_AUTO.csv 01:13:59 Note: on line 5 you have an observation with nrepeat > 5 but no BestEffort=1 notation on 01:14:00 not newer 01:14:00 AAVSO_MISC_CWT_AUTO.csv 01:14:00 line 5: maxX is 3 . This is greater than the warning level of 2 01:14:01 unknown filter name in line 5 [open] 01:14:01 not newer 01:14:02 AAVSO_MISC_FGU_AUTO.csv 01:14:03 not newer 01:14:03 AAVSO_MISC_GCO_AUTO.csv 01:14:03 not newer 01:14:04 AAVSO_MISC_HJZ_AUTO.csv 01:14:04 not newer 01:14:05 AAVSO_MISC_HQA_AUTO.csv 01:14:05 line 32: maxX is 2.5 . This is greater than the warning level of 2 01:14:05 not newer 01:14:06 AAVSO_MISC_MCJA_AUTO.csv 01:14:06 not newer 01:14:07 AAVSO_MISC_MRV_AUTO.csv 01:14:07 not newer 01:14:07 AAVSO_MISC_MZK_AUTO.csv 01:14:08 not newer 01:14:09 AAVSO_MISC_OAR_AUTO.csv 01:14:09 not newer 01:14:10 AAVSO_MISC_PYG_AUTO.csv 01:14:10 not newer 01:14:10 AAVSO_MISC_RMU_AUTO.csv 01:14:11 not newer 01:14:11 AAVSO_MISC_RNO_AUTO.csv 01:14:12 not newer 01:14:12 AAVSO_MISC_SBL_AUTO.csv 01:14:13 not newer 01:14:14 AAVSO_MISC_SFY_AUTO.csv 01:14:14 not newer 01:14:14 AAVSO_MISC_SGUA_AUTO.csv 01:14:15 not newer 01:14:15 AAVSO_MISC_WEL_AUTO.csv 01:14:16 not newer 01:14:16 AAVSO_MISC_WGR_AUTO.csv 01:14:17 not newer 01:14:17 AAVSO_MISC_WLP_AUTO.csv 01:14:18 not newer 01:14:18 AAVSO_MISC_ZTO_AUTO.csv 01:14:18 not newer 01:14:19 AAVSO_P124_Staels_AUTO.csv 01:14:19 line 6: maxX is 2.5 . This is greater than the warning level of 2 01:14:20 not newer 01:14:20 AAVSO_P129_SGUA_AUTO.csv 01:14:21 line 6: maxX is 2.2 . This is greater than the warning level of 2 01:14:21 not newer 01:14:21 AAVSO_P153_SFY_AUTO.csv 01:14:22 not newer 01:14:22 AAVSOnet Queue Manager Startup bomb out: ** cscript failed to exit in 30 sec. 01:14:22 Startup complete ACP console log closed 22-Jan-2023 01:14:22 UTC