ACP console log opened 11-Oct-2018 08:24:31 UTC This is ACP version 8.1 (build 2, Product Version 8.1.1) Licensed to Arne Henden 08:24:31 Start slew to FocusArea... 08:24:32 (wait for slew to complete) 08:25:26 (slew complete) 08:25:28 Search 15 deg-square area for possible stars 08:25:29 Looking for stars between mags 6 and 9 08:25:30 Found mag 6.0 star, GSC 1738-1977; nothing within 122 arcsec. 08:25:30 Star J2000 coordinates RA=00:41:36 Dec=24° 37' 45" 08:25:30 Using star at mag 6.0. Slew to star. 08:25:30 Start slew to AutoFocus... 08:25:31 (wait for slew to complete) 08:25:51 (slew complete) 08:25:51 Updating pointing... 08:25:51 Switching from I to V filter for pointing exposure 08:25:51 Focus change of 48 steps required 08:25:54 (taking 5 sec. exposure, V filter, binning = 4) 08:25:54 (using Image Quality readout mode) 08:25:55 (starting exposure) 08:26:01 (exposure complete) 08:26:07 (exposure complete and image downloaded) 08:26:07 Calibrating image... 08:26:07 **Calibration failed. Original image saved. 08:26:07 **MaxIm reports No suitable calibration groups were found. 08:26:09 Image finished 08:26:09 Plate-solve pointing image. 08:26:09 4 image stars found 08:26:09 49 catalog stars found 08:26:09 ** No matching stars found. Check your estimated center-point RA/Dec, and your image scaling and quality. 08:26:09 Start slew to offset... 08:26:11 (wait for slew to complete) 08:26:17 (slew complete) 08:26:17 (taking 5 sec. exposure, V filter, binning = 4) 08:26:17 (using Image Quality readout mode) 08:26:18 (starting exposure) 08:26:24 (exposure complete) 08:26:30 (exposure complete and image downloaded) 08:26:30 Calibrating image... 08:26:30 **Calibration failed. Original image saved. 08:26:30 **MaxIm reports No suitable calibration groups were found. 08:26:32 Image finished 08:26:32 Plate-solve pointing image. 08:26:32 3 image stars found 08:26:33 70 catalog stars found 08:26:33 ** No matching stars found. Check your estimated center-point RA/Dec, and your image scaling and quality. 08:26:33 Attempting all-sky plate solution (time-consuming)... 08:27:19 Failed: All-sky solution failed: Job 2839057 status: failure 08:27:20 Astrometry.net may be offline or image quality is too poor. 08:27:20 Start slew to AutoFocus... 08:27:21 (wait for slew to complete) 08:27:27 (slew complete) 08:27:27 (AF will use Image Quality readout mode) 08:27:27 Starting Autofocus... 08:27:28 08:27:28 System: Optec 08:27:29 ** Beginning Focus run ** 08:27:29 LS: -0.063042 RS: 0.062950 PID: 13.25 NFHFD: 15 08:27:30 Move direction: Out 08:27:31 Filter = V (slot 1) 08:27:31 Current position = 3040 08:27:32 Focus Start HFD: 20 08:27:33 Min/Max flux setting = 10/500K 08:27:33 Find star binning = 2x2 08:27:34 Inital exposure = 0.3 08:27:46 Focus binning = 1x1 08:27:50 Star is too close to frame edge or is too weak; increasing frame size 08:27:50 Increasing frame width 08:27:56 Star is too close to frame edge or is too weak 08:27:57 Increasing frame width 08:28:05 Target star found at X = 1672, Y = 1306 Flux = 19413 08:28:05 Focus exposure will be 0.30 sec 08:28:06 Position , HFD , Mean Best Focus , X , Y , Flux 08:28:06 3040 , 53.30 , 0 , 1672 , 1306 , 19413 08:28:13 Star is too close to frame edge or is too weak; increasing frame size 08:28:13 Increasing frame width 08:28:20 3304 , 22.65 , 0 , 1650 , 1320 , 54435 08:28:20 On correct side 08:28:21 Moving to start HFD 08:28:26 Star is too close to frame edge or is too weak; increasing frame size 08:28:26 Increasing frame width 08:28:30 Star is too close to frame edge or is too weak 08:28:31 Increasing frame width 08:28:37 Star is too close to frame edge or is too weak 08:28:47 Star is too close to frame edge or is too weak 08:28:47 Increasing Subframe Width, attempt 1 08:28:54 Star is too close to frame edge or is too weak 08:28:54 Increasing Subframe Width, attempt 2 08:29:02 Star is too close to frame edge or is too weak 08:29:03 Increasing Subframe Width, attempt 3 08:29:14 Star is too close to frame edge or is too weak 08:29:30 Star is too close to frame edge or is too weak 08:29:46 3346 , 00.00 , 0 , 1043 , 713 , 0 08:29:46 Move to Near Focus HFD 08:29:49 Star is too close to frame edge or is too weak; increasing frame size 08:29:50 Increasing frame width 08:29:53 3346 , 00.00 , 0 , 1023 , 693 , 267618 08:29:55 Star is too close to frame edge or is too weak; increasing frame size 08:29:55 Increasing frame width 08:29:58 Star is too close to frame edge or is too weak 08:29:59 Increasing frame width 08:30:02 Star is too close to frame edge or is too weak 08:30:11 Star is too close to frame edge or is too weak 08:30:11 Increasing Subframe Width, attempt 1 08:30:15 Star is too close to frame edge or is too weak 08:30:15 Increasing Subframe Width, attempt 2 08:30:19 Star is too close to frame edge or is too weak 08:30:19 Increasing Subframe Width, attempt 3 08:30:24 Star is too close to frame edge or is too weak 08:30:33 Star is too close to frame edge or is too weak 08:30:43 Star is too close to frame edge or is too weak 08:30:43 Can not measure HFD for this image 08:30:44 Moving to previous focus position of 3040 08:30:46 **AutoFocus failed. Check FocusMax log for details. 08:30:46 Slewing back to original position... 08:30:46 Start slew to AF return... 08:30:47 (wait for slew to complete) 08:30:59 (slew complete) 08:30:59 Autofocus finished. 08:30:59 ***AutoFocus failed. ACP console log closed 11-Oct-2018 08:30:59 UTC