+ | We inherited fiber from the Australia SONG project. This was about 500 meters of octagonal (50/70/95) fiber. We signed a contract with FiberTech Optica (FTO) in Canada to construct 2 separate 83m cables (for redundancy), | ||
+ | |||
+ | However, FTO has had issues with that fiber: | ||
+ | |||
+ | - for a short (2m) segment, they measured 25% lower throughput than the same length of circular fiber | ||
+ | |||
+ | - for an 83m segment, they measured 80% throughput at 632nm (not so far from the 86% that we were anticipating) | ||
+ | |||
+ | - most troubling, they say the fiber came off the spool very twisted and stressed, so that it coils itself back up, and is very difficult to work with. Injecting a slow beam, they estimate 40% loss in an output f/6 beam, and thus, likely worse for an input f/6 beam (which they will test). | ||
+ | the same spool for the Australia SONG node a few years ago, they looked up the notes for that, and found that the technician who handled that fiber described it as "devil fiber", | ||
+ | |||
+ | As of September 2024, we are considering how to proceed. | ||
+ | |||