fiber_run
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
fiber_run [2024/04/23 17:38] – holtz | fiber_run [2024/09/11 21:30] (current) – holtz | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Fiber ====== | ||
+ | |||
+ | ===== Fiber cladding and termination ===== | ||
+ | |||
+ | We inherited fiber from the Australia SONG project. This was about 500 meters of octagonal (50/70/95) fiber. We signed a contract with FiberTech Optica (FTO) in Canada to construct 2 separate 83m cables (for redundancy), | ||
+ | |||
+ | However, FTO has had issues with that fiber: | ||
+ | |||
+ | - for a short (2m) segment, they measured 25% lower throughput than the same length of circular fiber | ||
+ | |||
+ | - for an 83m segment, they measured 80% throughput at 632nm (not so far from the 86% that we were anticipating) | ||
+ | |||
+ | - most troubling, they say the fiber came off the spool very twisted and stressed, so that it coils itself back up, and is very difficult to work with. Injecting a slow beam, they estimate 40% loss in an output f/6 beam, and thus, likely worse for an input f/6 beam (which they will test). | ||
+ | the same spool for the Australia SONG node a few years ago, they looked up the notes for that, and found that the technician who handled that fiber described it as "devil fiber", | ||
+ | |||
+ | As of September 2024, we are considering how to proceed. | ||
+ | |||
+ | |||
+ | ===== Fiber conduit ===== | ||
+ | |||
==== Fiber run measurements, | ==== Fiber run measurements, | ||
Line 6: | Line 26: | ||
- From top of pier to bottom of pier: 4' 6" | - From top of pier to bottom of pier: 4' 6" | ||
- | - from bottom of pier to J3 junction box (concrete): 22' 3", including some estimate of service loop for azimuth motion | + | - from bottom of pier to J3 junction box (concrete): 22' 3", including some estimate of service loop for azimuth motion |
- from J3 junction box to J4 junction box : 98' | - from J3 junction box to J4 junction box : 98' | ||
Line 16: | Line 36: | ||
- from big box to small junction box where conduit enters APOGEE raceway: | - from big box to small junction box where conduit enters APOGEE raceway: | ||
- | - from small junction box up to wall in MARVELS room: 21' (but may need additional if service loops are needed for tight turns, e.g. from building | + | - from small junction box up to wall in MARVELS room: 21' (but may need additional if service loops are needed for tight turns, e.g. from building |
Line 27: | Line 47: | ||
MARVELS room wall length ~6 meters, so need additional depending on where spectrograph is located | MARVELS room wall length ~6 meters, so need additional depending on where spectrograph is located | ||
- | ==== Some images | + | ==== Images |
+ | |||
+ | == Small junction box into APOGEE raceway == | ||
+ | {{:: | ||
+ | |||
+ | |||
+ | |||
+ | == Turn inside APOGEE room == | ||
+ | {{:: | ||
+ | |||
+ | == New conduit around SDSS == | ||
+ | {{:: | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | {{:: | ||
- | \\ Small junction box into APOGEE raceway: | + | {{::fiber:fiber6.jpg? |
- | {{::fiber:fiber1.jpg |}} | + | |
- | {{::fiber:fiber4.jpg? | + | == Raw fiber from Polymicro == |
+ | {{::fiber:rawfiber1.jpg? | ||
- | \\ New conduit around SDSS | + | {{:: |
- | {{::fiber:fiber2.jpg? | + | {{::fiber:rawfiber3.jpg? |
- | {{:: | ||
- | {{:: | ||
- | {{:: | ||
fiber_run.1713893916.txt.gz · Last modified: 2024/04/23 17:38 by holtz