dome_control
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
dome_control [2024/02/10 19:43] – holtz | dome_control [2024/02/10 19:43] (current) – holtz | ||
---|---|---|---|
Line 24: | Line 24: | ||
The home sensor gets +5VDC and ground from the RPi, and receives a signal on a GPIO port that is normally low, but goes high when the home magnet is in proximity to the sensor.S | The home sensor gets +5VDC and ground from the RPi, and receives a signal on a GPIO port that is normally low, but goes high when the home magnet is in proximity to the sensor.S | ||
| Sensor wire | function | circular connector pin | color | level shifter | color| | | Sensor wire | function | circular connector pin | color | level shifter | color| | ||
- | | | | 1 | wht | | | | + | | |
- | | red | gnd | 2 | blk | RPi gnd | | | + | | red | gnd | 2 | blk | RPi gnd | | |
| blk | signal | 3 | brn | level B3 | gry | | | blk | signal | 3 | brn | level B3 | gry | | ||
- | | grn | +DC | 4 | red | RPi +5V | | | + | | grn | +DC | 4 | red | RPi +5V | | |
Low-level functions are implemented in the APOAshDome.py module. An ASCOM Alpaca interface was implemented using the templates from the [[https:// | Low-level functions are implemented in the APOAshDome.py module. An ASCOM Alpaca interface was implemented using the templates from the [[https:// |
dome_control.1707594181.txt.gz · Last modified: 2024/02/10 19:43 by holtz