User Tools

Site Tools


apo_lab_results

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
apo_lab_results [2025/10/13 02:10] jasonjapo_lab_results [2025/10/21 19:49] (current) – [September 2025 - fiber tests] jasonj
Line 21: Line 21:
 {{:test:seq1.png?direct&300}} {{:test:seq1.png?direct&300}}
  
-In the first sequence, Spool 2 legs 2 and 3 appear best, with leg 1 a bit worse. Leg 3 on spool 1 is about the same as leg 1 on spool 3, followed by leg 2, with poorest being leg 1 on Spool 1. This roughly matches the expectations from the {{:test:final_report_pf_02_compressed.pdf?linkonly|FTO test report}} (pages 9 and 12).+In the first sequence, Spool 2 legs 2 and 3 appear best, with leg 1 a bit worse. Leg 3 on spool 1 is about the same as leg 1 on spool 2, followed by leg 2, with poorest being leg 1 on Spool 1. This roughly matches the expectations from the {{:test:final_report_pf_02_compressed.pdf?linkonly|FTO test report}} (pages 9 and 12).
  
 Sequence 2: Sequence 2:
Line 36: Line 36:
 {{:test:seq4.png?direct&300}} {{:test:seq4.png?direct&300}}
  
-Tests after pulling fiber through conduit. After first set of fibers 1-3, refocussed spectrograph for a set with fiber 3, then rerouted fibers and refocussed Zaber for a set with fiber 2.+Tests after pulling fiber through conduit. After first set of fibers 1-3, we refocussed spectrograph for a set with fiber 3, then rerouted fibers and refocussed with Zaber for a set with fiber 2.
  
 ===== May 2025 ===== ===== May 2025 =====
apo_lab_results.1760321434.txt.gz · Last modified: by jasonj